Accessories and Options
All options are factory installed unless otherwise noted.
POWER OPTIONS:
Unit Power Connections
– Single-point terminal block connection(s) are provided as stan-
dard. The following power connections are available as options. (See electrical data for
specific voltage and options availability.)
Single-Point Supply Terminal Block
– Includes enclosure, terminal-block and intercon-
necting wiring to the compressors. Separate external protection must be supplied, by oth-
ers, in the incoming compressor-power wiring. (Do not include this option if either the Sin-
gle-Point Non-Fused Disconnect Switch or Single-Point Circuit Breaker options have been
included.)
Single-Point Non-Fused Disconnect Switch
– Unit-mounted disconnect switch(es) with
external, lockable handle (in compliance with Article 440-14 of N.E.C.)can be supplied to
isolate the unit power voltage for servicing. Separate external fusing must be supplied, by
others in the power wiring, which must comply with the National Electrical Code and/or local
codes.
Single-Point Circuit Breaker
– A unit mounted circuit breaker with external, lockable han-
dle (in compliance with NEC Article 440-14), can be supplied to isolate the power voltage for
servicing. (This option includes the Single-Point Power connection.)
Multiple Point Supply With Individual System Circuit Breakers –
Two unit-mounted cir-
cuit breakers, with external lockable handles (in compliance with NEC Article 440-14), can
be supplied to isolate the power voltage for servicing.
(SQ only)
Control Transformer
– Converts unit power voltage to 115-1-60 (0.5 or 1.0 kVA capacity).
Factory mounting includes primary and secondary wiring between the transformer and the
control panel.
Power Factor Correction Capacitors
– Will correct unit compressor power factors to a
0.90-0.95.
CONTROL OPTIONS:
High Ambient Kit –
Allows units to operate when the ambient temperature is above 115°F
(46°C). Includes sun shield panels and discharge pressure transducers.
Low Ambient Kit –
Standard units will operate to 30°F (-1°C). This accessory includes all
necessary components to permit chiller operation to 0°F (-18°C). (This option includes the
discharge pressure transducer /readout capability option.) For proper head pressure control
in applications below 30°F (-1°C) where wind gusts may exceed 5 mph, it is recommended
that optional condenser louvered enclosure panels also be included.
Language LCD and Keypad Display
– Spanish, French, German, and Italian unit LCD
controls and keypad display available. Standard language is English.
Содержание YLAA
Страница 4: ...JOHNSON CONTROLS FORM 150 72 EG6 516 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 35: ...FORM 150 72 EG6 516 JOHNSON CONTROLS 35 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 48: ...JOHNSON CONTROLS FORM 150 72 EG6 516 48 Wiring Diagram ...
Страница 49: ...FORM 150 72 EG6 516 JOHNSON CONTROLS 49 LD18444 Wiring Diagram Cont d ...