24
YORK INTERNATIONAL
FORM 201.19-NM1 (204)
The following options provide added protection:
Black
fi
n condenser coils –
Condenser coils con struct ed
using black epoxy coated Aluminum
fi
n stock for cor-
ro sion resistance comparable to copper fin coils in
typ i cal seashore locations.
Copper
fi
n condenser coils –
Coils constructed with
corrosion resistant copper
fi
ns. Not recommended in
areas where units may be exposed to acid rain.
Phenolic coated condenser coils –
Completed con-
dens er coil assemblies are covered with a cured Phe nol ic
coating. Probably the most suitable selection for sea-
shore locations where salt spray may come into con tact
with the
fi
ns, and other corrosive applications ex cept:
strong alkalis, oxidizers, and wet bromine, chlo rine, and
fl
uorine in concentrations greater than 100 PPM.
DX EVAPORATOR AND STARTER OPTIONS
300 PSIG (21 bar) Waterside Design Working
Pressure
–
The DX evaporator waterside is designed
and con struct ed for 300 PSIG (21 bar) working pressure.
(Factory-mounted)
1-1/2" (38 mm) Insulation –
Double thickness in su -
la tion provided for enhanced ef
fi
ciency.
Flange Accessory
–
Consists of raised face
fl
anges to
convert grooved water nozzles to
fl
anged evaporator
connections. Includes companion flanges for field-
mount ing. (See Page 33.)
Remote DX Evaporator
– Includes the main con-
dens ing unit less the evaporator, re frig er ant and liquid
line de vic es. The insulated evaporator and
fi
eld acces-
sory kits per re frig er ant circuit are sup plied separately.
The condensing unit is shipped with a nitrogen holding
charge and the evaporator is shipped with a ni tro gen
hold ing charge.
Flow Switch Accessory
– Johnson Controls model
F61MG-1C Vapor-proof SPDT, NEMA 4X switch, 150
PSIG (10 bar) DWP, -20°F to 250°F (-29°C to 121°C),
with 1" NPT (IPS) con nec tion for upright mounting in
horizontal pipe. A
fl
ow switch must be
fi
eld installed
with each unit. Optional 300 PSIG switch available.
Star-Delta Compressor Motor Starter
– Provides ap-
proximately 65% reduced inrush current compared to
across-the-line start (Factory-mounted).
UNIT ENCLOSURES OPTIONS
Wire enclosure
–
Heavy gauge welded wire mesh
guards mounted on the exterior of the unit (Factory- or
fi
eld-mounted).
Louvered panels and wired guards
–
Louvered pan-
els mounted over the exterior condenser coil faces, and
heavy gauge welded wire mesh guards mounted around
the bottom of the unit (Factory- or
fi
eld-mounted).
Louvered panels (condenser coils only)
–
Lou vered
panels are mounted over the exterior condenser coil faces
on the sides of the unit to visually screen and pro tect the
coils (Factory- or
fi
eld-mounted).
Louvered panels (full unit) enclosure
–
Louvered
panels over condenser coils and around the bottom of
the unit (Factory- or
fi
eld-mounted).
FAN OPTIONS
High static fans:
Fans and motors suitable for High
External Static conditions to 100 Pa.
SOUND REDUCTION OPTIONS
Low speed fans
–
Reduced RPM fan motors and al ter -
na tive fan selection for low noise applications.
Compressor sound enclosures
–
Acoustically
treated metal compressor enclosures.
VIBRATION ISOLATION
Neoprene pad isolation
–
Recommended for normal
installations. (Field-mounted)
1" (25 mm) spring isolators
–
Level adjustable, spring
and cage type isolators for mounting under the unit base
rails (Field-mounted).
2" (51 mm) seismic spring isolators
–
Restrained
Spring-Flex Mountings incorporate welded steel hous-
ing with vertical and horizontal limit stops. Housings de-
signed to withstand a minimum 1.0 g accelerated force in
all directions to 2" (51 mm). Level ad just able, de
fl
ec tion
may vary slightly by application. (Field- mount ed).
Product Description
Содержание YCAS0130
Страница 45: ...45 YORK INTERNATIONAL FORM 201 19 NM1 204 5 This page intentionally left blank...
Страница 47: ...47 YORK INTERNATIONAL FORM 201 19 NM1 204 6 This page intentionally left blank...
Страница 63: ...63 YORK INTERNATIONAL FORM 201 19 NM1 204 This page intentionally left blank 7...
Страница 73: ...73 YORK INTERNATIONAL FORM 201 19 NM1 204 LD09239 FIG 22B CONTROL PANEL COMPONENT LOCATION 7...
Страница 75: ...75 YORK INTERNATIONAL FORM 201 19 NM1 204 7 LEGEND LD09241...
Страница 76: ...76 YORK INTERNATIONAL FORM 201 19 NM1 204 Technical Data LD03282 LD03283 2 ACE MOTOR PROTECTOR MODULE LD03284...
Страница 77: ...77 YORK INTERNATIONAL FORM 201 19 NM1 204 7 CONNECTION DIAGRAM SYSTEM WIRING LD09242...
Страница 78: ...78 YORK INTERNATIONAL FORM 201 19 NM1 204 Technical Data COMPRESSOR TERMINAL BOX LD09243...
Страница 79: ...79 YORK INTERNATIONAL FORM 201 19 NM1 204 7 LD09373 ELEMENTARY DIAGRAM CONTROL CIRCUIT...
Страница 81: ...81 YORK INTERNATIONAL FORM 201 19 NM1 204 7 This page intentionally left blank...
Страница 113: ...113 YORK INTERNATIONAL FORM 201 19 NM1 204 COMPRESSOR COMPONENTS CONT D FIG 41 COMPRESSOR COMPONENTS LD03670 7...
Страница 121: ...121 YORK INTERNATIONAL FORM 201 19 NM1 204 7 This page intentionally left blank...
Страница 193: ...193 YORK INTERNATIONAL FORM 201 19 NM1 204 8 This page intentionally left blank...