ZQ04 to 06 High Static Indoor Blower - Without Powered Convenience Outlet
Table 11: ZQ04-06 High Static Indoor Blower - Without Powered Convenience Outlet
Compressor 1
Compressor 2
Electric Heat Field
Installed Kit 2EK045*
4
Min Disconnect Rating
Min Disconnect Rating
/ Pwr Exh
Si
ze
(T
on
s)
N
om
in
al
U
ni
t V
ol
ta
ge
RLA LRA MCC RLA LRA MCC
OD Fan Motors (each)
Supply Blower Motor
Pwr Exh Motor
Pwr Conv Outlet
Model kW Stages Amps
1
MCA
(Amps)
2, 3
Min Fuse
/ Breaker
Size (Amps)
Max Fuse
/ Breaker
Size (Amps)
FLA LRA
MCA
w/Pwr Exh (Amps)
Min Fuse
/ Breaker
Size w/ Pwr Exh (Amps)
Max Fuse
/ Breaker
Size w/ Pwr Exh (Amps)
FLA LRA
None
-
-
-
19.6
20
30
20
99 20.7 25
30
21 101
10625 4.9
1
13.6
23.5
25
30
22
99 24.9 25
30
23 101
11125 7.9
1
21.9
33.9
35
35
31
99 35.3 40
40
32 101
208-3-60 10.4 73
16
1.4
5.2
1.1
11625 12
1
33.3
48.1
50
50
44
99 49.5 50
50
46 101
None
-
-
-
19.6
20
30
20 101 20.6 25
30
21 104
10625 6.5
1
15.6
26
30
30
24 101 27.3 30
30
25 104
11125 10.5
1
25.3
38.1
40
40
35 101 39.4 40
40
36 104
230-3-60 10.4 73
16
1.4
5.2
1
11625 16
1
38.5
54.6
60
60
50 101 55.9 60
60
51 104
None
-
-
-
10.7
15
15
11
52 11.2 15
15
11
54
10646
6
1
7.2
12.3
15
15
11
52 12.9 15
15
12
54
11146 11.5
1
13.8
20.5
25
25
19
52 21.1 25
25
19
54
460-3-60 5.8 38
9
0.8
2.6
0.5
11446 14
1
16.8
24.3
25
25
22
52 24.9 25
25
23
54
None
-
-
-
7.4
15
15
7
48 7.8 15
15
8
49
11058 9.2
1
8.9
13.6
15
15
13
48 14.1 15
15
13
49
04 (3)
575-3-60 3.8 36.5
6
0.6
2
0.4
11458 13.8
1
13.3
19.1
20
20
18
48 19.6 20
20
18
49
None
-
-
-
23.7
25
35
23 109 24.8 25
35
25 111
10625 4.9
1
13.6
23.7
25
35
23 109 24.9 25
35
25 111
11125 7.9
1
21.9
33.9
35
35
31 109 35.3 40
40
32 111
208-3-60 13.7 83.1 21
1.4
5.2
1.1
11625 12
1
33.3
48.1
50
50
44 109 49.5 50
50
46 111
None
-
-
-
23.7
25
35
23 111 24.7 25
35
24 114
10625 6.5
1
15.6
26
30
35
24 111 27.3 30
35
25 114
11125 10.5
1
25.3
38.1
40
40
35 111 39.4 40
40
36 114
230-3-60 13.7 83.1 21
1.4
5.2
1
11625 16
1
38.5
54.6
60
60
50 111 55.9 60
60
51 114
None
-
-
-
11.2
15
15
11
55 11.7 15
15
12
57
10646
6
1
7.2
12.3
15
15
11
55 12.9 15
15
12
57
11146 11.5
1
13.8
20.5
25
25
19
55 21.1 25
25
19
57
460-3-60 6.2 41
10
0.8
2.6
0.5
11446 14
1
16.8
24.3
25
25
22
55 24.9 25
25
23
57
None
-
-
-
8.6
15
15
9
45
9
15
15
9
45
11058 9.2
1
8.9
13.6
15
15
13
45 14.1 15
15
13
45
05 (4)
575-3-60 4.8 33
8
0.6
2
0.4
11458 13.8
1
13.3
19.1
20
20
18
45 19.6 20
20
18
45
1
Minimum Circuit Ampacity.
2
Dual Element, Time Delay Type.
3
HACR type per NEC.
4
Non-fused Disconnect, Verify on the unit nameplate that the disconnect is properly sized for the application. Units with field
installed electric heat kits may exceed the factory installed disconnect amperage rating.
INSTALLATION MANUAL ZQ SERIES 3 - 5 ton 60 Hertz R-410A
30
Johnson Controls Ducted Systems
Содержание ZQ Series
Страница 2: ...2 INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A Johnson Controls Ducted Systems ...
Страница 8: ...Nomenclature INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A 8 Johnson Controls Ducted Systems ...
Страница 87: ...Start Up Sheet INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A 87 Johnson Controls Ducted Systems ...
Страница 88: ... INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A 88 Johnson Controls Ducted Systems ...
Страница 89: ... INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A 89 Johnson Controls Ducted Systems ...
Страница 90: ... INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A 90 Johnson Controls Ducted Systems ...
Страница 91: ... INSTALLATION MANUAL ZQ SERIES 3 5 ton 60 Hertz R 410A 91 Johnson Controls Ducted Systems ...