5188238-YIM-D-0518
20
Johnson Controls Ducted Systems
XN036-060 - Without Powered Convenience Outlet (Direct Drive)
Size
(Tons)
Volt
Compressors
(each)
OD Fan
Motors
(each)
Supply
Blower
Motor
Pwr
Conv
Outlet
Electric Heat Option
MCA
1
(Amps)
Max
Fuse
2
/
Breaker
3
Size
(Amps)
RLA LRA MCC
FLA
FLA
FLA
Model
kW
Stages
Amps
036
(3.0)
208-1-60 16.7
109
26
1.3
6
0
NONE
-
-
-
28.2
35
E05
4
1
19.2
52.2
60
E07
5.6
1
26.9
61.8
70
E10
8
1
38.5
76.3
80
E15
11.9
2
57.2
99.7
100
E20
15.9
2
76.4
123.7
125
230-1-60 16.7
109
26
1.3
6
0
NONE
-
-
-
28.2
35
E05
5.3
1
22.1
55.8
60
E07
7.5
1
31.2
67.2
70
E10
10.6
1
44.2
83.4
90
E15
15.9
2
66.2
111
125
E20
21.2
2
88.3
138.6
150
208-3-60 11.2
88
17.5
1.3
6
0
NONE
-
-
-
21.3
30
E05
4
1
11.1
35.2
40
E07
5.6
1
15.5
40.7
45
E10
8
1
22.2
49.1
50
E15
11.9
2
33
62.6
70
E20
15.9
2
44.1
76.5
80
230-3-60 11.2
88
17.5
1.3
6
0
NONE
-
-
-
21.3
30
E05
5.3
1
12.7
37.2
45
E07
7.5
1
18
43.9
50
E10
10.6
1
25.5
53.2
60
E15
15.9
2
38.2
69.1
70
E20
21.2
2
51
85
90
048
(4.0)
208-1-60 19.6
130
30.5
2.8
7.6
0
NONE
-
-
-
34.9
45
E05
4
1
19.2
58.9
70
E07
5.6
1
26.9
68.6
80
E10
8
1
38.5
83
90
E15
11.9
2
57.2
106.4
110
E20
15.9
2
76.4
130.5
150
230-1-60 19.6
130
30.5
2.8
7.6
0
NONE
-
-
-
34.9
45
E05
5.3
1
22.1
62.5
70
E07
7.5
1
31.2
74
80
E10
10.6
1
44.2
90.1
100
E15
15.9
2
66.2
117.7
125
E20
21.2
2
88.3
145.3
150
208-3-60 13.7 83.1
21.4
2.8
7.6
0
NONE
-
-
-
27.5
35
E05
4
1
11.1
41.4
50
E07
5.6
1
15.5
47
50
E10
8
1
22.2
55.3
60
E15
11.9
2
33
68.8
70
E20
15.9
2
44.1
82.7
90
230-3-60 13.7 83.1
21.4
2.8
7.6
0
NONE
-
-
-
27.5
35
E05
5.3
1
12.7
43.5
50
E07
7.5
1
18
50.1
60
E10
10.6
1
25.5
59.4
60
E15
15.9
2
38.2
75.3
80
E20
21.2
2
51
91.3
100