background image

Entering the value for each parameter:

Press Ent to enter Parameter setting
Press Ent to enter Start value
Use the Left/Right arrow for the digit to be set, use the numeric keypad to enter the values, after entering the correctalue use ENT to confirm and to leave the parameter, or use CAN to cancel the
input value. Use Up and Down arrow to select the next parameter to be set.
Press NEXT key to enter the next page of parameters to be set or PREV to previous page.
By pressing MAIN or CAN key you return to Main Menu screen.

Rundown data history

The tool has a memory for the rundown data of the last 50 cycles.   

Select RUNDOWN DATA with the Up and Down arrow keys and press ENT to enter this function.​

​Item

​Explanation

​Rundown sequence

​1 - 99

Содержание YZ-T800A

Страница 1: ...YZ T800A MANUAL EN www rami yokota com...

Страница 2: ...to our website Make sure that during operation of the tool no projectiles can be generated this can be dangerous and may cause injuries Make sure that the work piece is securely fixed Make sure that t...

Страница 3: ...t in short circuit of the terminals of the battery pack and fire Do not expose battery cartridge to water or rain A battery short can cause large current flow overheating possibly burns and even a bre...

Страница 4: ...s too low 10 Value too low 11 Number of impulses too high 12 Cycle OK The torque reached in the joint is depending on 3 settings The motor speed 1 Output value 2 Cut value 3 Tightening time 4 Value ri...

Страница 5: ...s output with the relief valve mechanical adjustment on the impulse mechanism Always take off the battery when adjusting the torque output with the relief valve on the impulse mechanism Use the TF pin...

Страница 6: ...sult setting item and set value 3 Function key Switching of tightening screen setting screen and or of display screen 4 Numeric key Enter the set value 5 CAN key Return to the previous screen 6 ENT ke...

Страница 7: ...arameter or use CAN to cancel the input value Use Up and Down arrow to select the next parameter to be set Press NEXT key to enter the next page of parameters to be set or PREV to previous page By pre...

Страница 8: ...o enter this function Result 20 the average on which the tool has shut off NUM 6 number of impulses including the impulses lower than start value 6 12 15 19 20 21 the value of each impulse If you have...

Страница 9: ...value Switch value Cut value Max value 10 150 10 Switch value Value to switch motor speed from middle speed to high speed Switch value Cut value Max value 10 150 10 Cut value Shut off value as soon as...

Страница 10: ...h speed a little higher Set the minimum and maximum number of impulses according the hardness of the application Set the start value and the switch value according the hardness of the application The...

Страница 11: ...Over voltage Error Over current Error Abnormal pulse signal Memory Error Please send the tool for repair to an authorized service shop Extreme low environment temperature can show a wire breakage erro...

Страница 12: ...pack Overheat alarm 3 Lighting Please wait until release LED lamp lights off 1 Low voltage error may operate when using a battery pack whose performance has deteriorated due to deterioration low temp...

Страница 13: ...of warranty claims is no part of the warranty arrangements Also claims for loss of production and or other damages are excluded from this warranty Repairs under warranty can only be considered when t...

Страница 14: ...www rami yokota com...

Отзывы: