Maintenance.
Select MAINTENACE with the up and down arrow keys and press ENT.
Selecting SETTING INIT or DATA CLEAR with the up and down arrow and press ENT.
1: SETTING INIT = initializing the parameter setting back to default value.
2: DATA CLEAR: deleting all data stored in RUNDOWN DATA and PULSE DATA.
Explanation of each parameter
Parameter
Range
Default value
Start value
Display start value, the value below the start value will be ignored, judgement will not be
made. Impulses below this start value will not be counted for the max number of
impulses.
Start value ≤ Switch value ≤ Cut value ≤ Max value
10 ~ 150
10
Switch value
Value to switch motor speed from middle speed to high speed
Switch value ≤ Cut value ≤ Max value
10 ~ 150
10
Cut value
Shut-off value, as soon as the tool reaches this value the tool will shut-off
Cut value ≤ Max value
20 ~ 150
20
Max value
If this value is exceeded the tightening will be judged as NOK
Max value ≥ Cut value
20 ~ 150
20
Low speed rpm
Tool rpm at the first step of the trigger
1200 ~ 1500
1200
Middle speed rpm
Tool rpm at the second step of the trigger
1500 ~ 3000
2000
High speed rpm
Tool rpm switches from middle speed to high speed at reaching the switch value
1500 ~ 4800 YZ-T600
2000 ~ 4800 others
3000
Average num
The value is calculated as an average over the last 2 or 3 impulses
2 ~ 3
3
Содержание YZ-T800A
Страница 1: ...YZ T800A MANUAL EN www rami yokota com...
Страница 14: ...www rami yokota com...