Instruction Sheet
XCede® HD Backplane Receptacle
STS-X-XXX
HDTF Series
Rev. A
CAT-RE-HDTF-X – HDTF-RA Stiffener Rework Tool
Date: 8/27/2019
Page 1
This is a controlled document and is subject to change (printed versions are not controlled)
1. INTRODUCTION
This instruction sheet covers the use of the SAMTEC XCede HD Stiffener Rework Tool CAT-RE-HDTF-X. This
tool assists in the removal and insertion of the metal stiffener on the HDTF-RA connector. This tool can be
used on individual modules as well as BSP modules.
2. CUSTOMER SERVICE
Further tooling and product application assistance is available by contacting the
Samtec Application
Service Line +1-800-726-8329 (+1-812-944-6733)
8:00 AM to 5:00 PM EST. To expedite your
inquiry, have the pertinent part numbers for the product and tooling.
3. DESCRIPTION
Each tool has the side marked with the tooling number. Make sure it matches the tooling number specified in
this document.
4. REMOVAL
The following steps are recommended for removing the HDTF-RA stiffener:
1.
Prior to removing the stiffener, verify the stiffener removal tool (
Figure 1
) is in proper working order
and condition. Ensure all stiffener engagement pins are present and protruding at least 0.030” from
each opposing face of the pin block, as seen in
Figure 2
. If any pins are missing, bent, or broken,
remove and replace them.
2.
Ensure that the stiffener removal tool is in the fully-closed position (tighten handle clockwise until hard
stop).
3.
Orient the tool above the connector, so that the pins are facing towards the connector, and the tool’s
plastic insert is facing up. The tool’s handle should be pointed in the direction of the connector mating
surface shown in
Figure 3
.
FIGURE 1
FIGURE 2
0.030”
minimum