MTR Configuration (MTR Configuration)
Select the functions of signal input Ch A to Ch H for motor evaluation function 1 and motor evaluation function 2.
• Single Motor (revolution signal: pulse) (Single Motor (Speed:Pulse))
The revolution signals are the pulses of phases A, B, and Z.
/MTR1
/MTR2
Function Signal
Ch A
Ch E
Torque
Analog/pulse
Ch B
Ch F
Speed A
Pulse A phase (used for velocity measurement)
Ch C
Ch G
Speed B
Pulse B phase (used for rotation direction
detection)
Ch D
Ch H
Speed Z
Pulse Z phase (used for electrical angle
reference measurement)
Motor number assignments (Motor 1, Motor 3)
Motor 3
Motor 1
• Single Motor (revolution signal: analog) (Single Motor (Speed:Analog))
The revolution signals are analog.
/MTR1
/MTR2
Function Signal
Ch A
Ch E
Torque
Analog/pulse
Ch B
Ch F
-
Not use
Ch C
Ch G
Speed
Analog
Ch D
Ch H
-
Not use
Motor number assignments (Motor 1, Motor 3)
Motor 3
Motor 1