background image

Standard Specifications 

IM 01G05B03-01E 1st Edition 

A Standard Specifications 

US300FM 

 

General 

Fluid: 

Liquid (Turbidity < 10,000 mg/L, Sound velocity 800 to 
3,500 m/s, Temperature –30 to +200°C / –22 to +392°F) 

Measured Quantities: 

Volume flow, mass flow (by setting density), flow 
velocity, sound velocity in the fluid 

Measuring Principal: 

Transit time method using ultrasonic signal 

Pipe Sizes: 

25 to 6,500 mm (1 to 255 inches) (covered by three 
types of transducers) 

Pipe and Lining Materials: 

Carbon steel, Stainless steel, Grey cast iron, Ductile 
iron, Copper, Glass, PVC, etc. 

Flow Velocity Range: 

±0.01 to ±25 m/s (±0.033 to ±82 ft/s) 

Resolution: 

0.025 cm/s (0.01 in/s) 

Repeatability: 

0.15% of reading ±0.01 m/s (0.033 ft/s) 

Accuracy: 

(Note)  Under fully developed rotationally symmetrical flow 

profile 

Volumetric flow: 

±1 to 3% of reading ±0.01 m/s (0.033 ft/s) 
depending on pipe geometry and accuracy 
of entered pipe dimensions. 

Flow velocity: 

±0.5% of reading ±0.01 m/s (0.033 ft/s) 
over sonic path 

Measuring Cycle: 

100 to 1000 Hz (per one channel) 

Straight Pipe Run in the Upstream: 

10 to 50 pipe diameters, depending on the kind of flow 
disturbances 

 

Ultrasonic Flowmeter, Main Unit 

Housing Material: 

Aluminum 

Painting: 

Front cover: 

Deep sea moss green, Polyuretane and 
acrylic resin corrosion-resistance 
waterbased coating 

Back cover: 

Agate grey, Polyester resin corrosion-
resistance powder coating 

Degrees of Protection: 

 IP65 (EN60529) 

Mounting Method: 

 Wall mounting 

  Pipe mounting fixture (for 2-inch pipe, optional) 

Measuring Input : 

One or two (dual) (Channel A, Channel B). 

Current Output: 

  One or two 

  Range 4 to 20 mA (Load resistance 0 to 500 

Note:  The current outputs may temporarily turn unstable 

during the power-on sequence (including restarting 
after power failure) and parameter display / setting 
mode. Take care of your process not to be affected 
by this behavior. 

Frequency Output: 

  None (standard), or one (optional) 

  Range 0 to 1 kHz 

  Contact type: Open-collector, 24 V / 4 mA 

Binary Output: 

  None (standard), one, or two (optional) 

  Contact type: Open-collector, 24 V / 4 mA 

Input / Output Terminal Configuration: 

Screw-type pillar terminals 

LCD Display: 

2 line x 16 character LCD display with backlight. 
Configurable to display two measured values (e.g., flow 
rate and total flow) simultaneously, or to display values 
from optional dual input channels alternately. 

Keyboard: 

15 keys (numerical, functional, or both) including four 
arrow-shaped keys for cursor operation, enabling easy 
access through its interactive menu structure. 

Display Language: 

Czech, Danish, Dutch, English (default), French, 
German, Norwegian, Polish, Turkey 

Flow Measurement: 

Flow velocity, Volume flow, Mass flow 

Sound Velocity / Signal Amplitude Measurement (On-
line): 

Sound velocity and signal amplitude in the fluid 
available on-line simultaneously with flow measurement. 

Totalization Function: 

Totalizes the volume flow or mass flow. Ten-digit 
number for both forward/reverse directions of each 
channel. 

Damping Function: 

Time constant 0 to 100 seconds, moving average. 

Sound Velocity Measurement (Off-line): 

Measures the sound velocity of unknown fluid starting 
from its estimated sound velocity. The result can be 
transferred to the current fluid parameter. 

Содержание US300FM

Страница 1: ...ite White Perform soldering Finish the brown cables as well as white cables You do not connect the thin lines to any terminals Brown 12 2 Less than 10mm 12 2 Perform soldering Shield line Cable shield...

Страница 2: ...ccurs A Tokuchu request is necessary for Submersible type However the diameter must be over 100 mm Changes to the section 3 5 5 Connection to the Power Supply page 20 AC power supply DC power supply T...

Страница 3: ...y this behavior Addition and deletion to the section 4 1 1 Key Operations page 23 and related pages Refer to the following table for the function of corresponding key operations The correct explanatio...

Страница 4: ...a wall thickness probe or some other ways and avoid mounting the transducers on such parts Attention Instructions for using Acoustic couplant weatherproof type Shin Etsu Silicone 1 COMPONENT RTV are a...

Страница 5: ...the section 14 5 Activation of a Pulse Output page 95 Maximum pulse output rate is 2 pulse per second 20 Set the Pulse Value and the Pulse Width so that the actual maximum flow in the pipe is less th...

Страница 6: ...Measuring Input One or two dual Channel A Channel B Current Output One or two Range 4 to 20 mA Load resistance 0 to 500 Note The current outputs may temporarily turn unstable during the power on seque...

Страница 7: ...tion only for test service maintenance purposes Time Programmable Measurement Function Automatic start stop of the measurement without human operation using internal clock for specific systems Can be...

Страница 8: ...suring data set in graphic format Marker type and color for each line of values selectable Scales for time axis and value axis can be changed from default condition of automatic scaling Graph printing...

Страница 9: ...th 4 4 m 14 4 ft cable CH Large High with 4 4 m 14 4 ft cable DG Very large General with 12 m 39 4 ft cable N Always N Fixing band strap and clips 6 B For 25 to 1 400 mm 1 to 55 in Two fixing bands On...

Страница 10: ...g fixture short ruler type for transducers medium pipe size type temperature range 30 to 200 C 22 to 392 F set of two blocks with 120 mm 4 7 in ruler USPA054 Mounting fixture standard type for transdu...

Страница 11: ...flowmeter US300FM Unit mm inch Transducers US300FT B Transducers US300FT C US300FT D Transducers X m inch Y m inch X Y m inch Weight kg lb US300FT B 2 0 78 7 1 0 39 4 3 0 118 1 0 9 1 98 US300FT C 2 0...

Страница 12: ...annel A P1 P1 Current output AR ARS Upstream transducer signal for channel A P2 P2 Current output when specifying two current outputs BV BVS Downstream transducer signal for channel B P3 P3 Frequency...

Отзывы: