3-14
IM 77C01H01-10EN
3.4 Other Settings
3.4.1
Start of Optional Integration
[Procedure]
1. To start optional integration, write data to the D register or the I relay in the table below.
The data type is integer.
D Register Reference No. H No. I relay
Description
Effective Range
D0062
40062
003D
I0013
Start of optional integration
(D0003 to D0006)
If other than 1: Invalid
If 1: Optional integration
is started
Note
The D register and the I relay in the table above have the same functions.
[Example]
To start optional integration:
For station number 01, use PC link communication (without checksum) and the random write
command as shown below:
[Command]
[STX] 01010WRW01D0062, 0001 [ETX] [CR]
[Response]
[STX] 0101OK [ETX] [CR]
3.4.2
Stop of Optional Integration
[Procedure]
1. To stop optional integration, write data to the D register or to the I relay in the table
below. The data type is integer.
D Register Reference No. H No. I relay
Description
Effective Range
D0063
40063
003E
I0014
Stop of optional integration
(D0003 and D0004)
If other than 1: Invalid
If 1: Optional integration is
stopped
Note
The D register and the I relay in the table above have the same functions.
[Example]
To stop optional integration:
For station number 01, use PC link communication (without checksum) and the random write
command as shown below:
[Command]
[STX] 01010WRW01D0063, 0001 [ETX] [CR]
[Response]
[STX] 0101OK [ETX] [CR]