![YOKOGAWA F3YP14-0N Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/yokogawa/f3yp14-0n/f3yp14-0n_user-manual_910940054.webp)
6-1
IM 34M6H55-02E
1st Edition : Apr.1.2002-00
6. Input/Output
Relays
The positioning module has 32 output relays and 32 input relays for interfacing to the
FA-M3 CPU module. For details on each input/output relay, refer to Chapter 7,
“Accessing Modules.”
CAUTION
For the F3YP14-0N, NEVER set the output relays for axes 5 to 8. Input relays for axes 5
to 8 have no meaning.
6.1 Output
Relays
Table 6.1 lists the output relays available in this positioning module.
Table 6.1
Output Relays
Output relay
number
Operation when ON
Output relay
number
Operation when ON
Y
VVV
33
Axis 1, Execute Command
Y
VVV
49
Axis 1, Positive-direction Jog Stepping
Y
VVV
34
Axis 2, Execute Command
Y
VVV
50
Axis 2, Positive-direction Jog Stepping
Y
VVV
35
Axis 3, Execute Command
Y
VVV
51
Axis 3, Positive-direction Jog Stepping
Y
VVV
36
Axis 4, Execute Command
Y
VVV
52
Axis 4, Positive-direction Jog Stepping
Y
VVV
37
Axis 5, Execute Command
Y
VVV
53
Axis 5, Positive-direction Jog Stepping
Y
VVV
38
Axis 6, Execute Command
Y
VVV
54
Axis 6, Positive-direction Jog Stepping
Y
VVV
39
Axis 7, Execute Command
Y
VVV
55
Axis 7, Positive-direction Jog Stepping
Y
VVV
40
Axis 8, Execute Command
Y
VVV
56
Axis 8, Positive-direction Jog Stepping
Y
VVV
41
Axis 1, Stop Immediately
Y
VVV
57
Axis 1, Negative-direction Jog Stepping
Y
VVV
42
Axis 2, Stop Immediately
Y
VVV
58
Axis 2, Negative-direction Jog Stepping
Y
VVV
43
Axis 3, Stop Immediately
Y
VVV
59
Axis 3, Negative-direction Jog Stepping
Y
VVV
44
Axis 4, Stop Immediately
Y
VVV
60
Axis 4, Negative-direction Jog Stepping
Y
VVV
45
Axis 5, Stop Immediately
Y
VVV
61
Axis 5, Negative-direction Jog Stepping
Y
VVV
46
Axis 6, Stop Immediately
Y
VVV
62
Axis 6, Negative-direction Jog Stepping
Y
VVV
47
Axis 7, Stop Immediately
Y
VVV
63
Axis 7, Negative-direction Jog Stepping
Y
VVV
48
Axis 8, Stop Immediately
Y
VVV
64
Axis 8, Negative-direction Jog Stepping
Note: Replace “
VVV
” with the number of the FA-M3 slot where the positioning module is installed.
z
z
z
z
Execute Command Relay (Y
V
V
V
VV
V
V
VV
V
V
V
33 to Y
V
V
V
VV
V
V
VV
V
V
V
40)
Turning on one of these relays causes the axis concerned to start operating according to
the current command code stored in the command parameter. When the operation
defined by the command code has been successfully executed, the Execute Command
ACK relay (X
VVV
01 to X
VVV
08) turns on. Turning off the Execute Command relay
turns off the Execute Command ACK relay (X
VVV
01 to X
VVV
08).
z
z
z
z
Stop Immediately Relay (Y
V
V
V
VV
V
V
VV
V
V
V
41 to Y
V
V
V
VV
V
V
VV
V
V
V
48)
Turning on one of these relays causes the axis concerned to stop immediately without
going through deceleration. When the Stop Immediately operation has been
successfully executed, the Stop Immediately ACK relay (X
VVV
09 to X
VVV
16) turns
on. Turning off the Stop Immediately relay turns off the Stop Immediately ACK relay
(X
VVV
09 to X
VVV
16).
z
z
z
z
Positive-direction Jog Stepping Relay (Y
V
V
V
VV
V
V
VV
V
V
V
49 to Y
V
V
V
VV
V
V
VV
V
V
V
56)
The axis moves in the positive direction as long as this relay stays on.
z
z
z
z
Negative-direction Jog Stepping Relay (Y
V
V
V
VV
V
V
VV
V
V
V
57 to Y
V
V
V
VV
V
V
VV
V
V
V
64)
The axis moves in the negative direction as long as this relay stays on.
Содержание F3YP14-0N
Страница 13: ...Blank Page ...
Страница 15: ...Blank Page ...
Страница 23: ...Blank Page ...
Страница 53: ...Blank Page ...
Страница 60: ...7 5 IM 34M6H55 02E 1st Edition Apr 1 2002 00 Figure 7 2 Set Parameter Program ...
Страница 65: ...7 10 IM 34M6H55 02E 1st Edition Apr 1 2002 00 Figure 7 6 Jog Stepping Program ...
Страница 69: ...7 14 IM 34M6H55 02E 1st Edition Apr 1 2002 00 Figure 7 9 Origin Search Program ...
Страница 77: ...7 22 IM 34M6H55 02E 1st Edition Apr 1 2002 00 Figure 7 15 Positioning Operation Program ...
Страница 111: ...Blank Page ...
Страница 127: ...Blank Page ...