:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:PSPCount (Sample Point
Count %)
Function Sets the upper and lower limits of the error rate for
the number of sampled data points of the element or
queries the current setting.
Syntax
:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:PSPCount {<NRf>,<NRf>}
:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:PSPCount?
<x> of SELect<x> = 1 to 4
<x> of ELEMent<x> = 1 to 4
<NRf> = 0 to 100 (%)
Example
:GONOGO:TELECOMTEST:SELECT1:MASK:
ELEMENT1:PSPCOUNT 1,2
:GONOGO:TELECOMTEST:SELECT1:MASK:
ELEMENT1:PSPCOUNT? -> :GONOGO:
TELECOMTEST:SELECT1:MASK:ELEMENT1:
PSPCOUNT 2.000E+00,1.000E+00
:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:PWCount (Wave Count %)
Function Sets the upper and lower limits of the error rate for
the number of acquisitions of the element or queries
the current setting.
Syntax
:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:PWCount {<NRf>,<NRf>}
:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:PWCount?
<x> of SELect<x> = 1 to 4
<x> of ELEMent<x> = 1 to 4
<NRf> = 0 to 100 (%)
Example
:GONOGO:TELECOMTEST:SELECT1:MASK:
ELEMENT1:PWCOUNT 1,2
:GONOGO:TELECOMTEST:SELECT1:MASK:
ELEMENT1:PWCOUNT? -> :GONOGO:
TELECOMTEST:SELECT1:MASK:ELEMENT1:
PWCOUNT 2.000E+00,1.000E+00
:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:SPCount (Sample Point
Count)
Function Sets the upper and lower limits of the number of
sampled data points for the element that results in
error or queries the current setting.
Syntax
:GONogo:TELecomtest:SELect<x>:MASK:E
LEMent<x>:SPCount {<NRf>,<NRf>}
:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:SPCount?
<x> of SELect<x> = 1 to 4
<x> of ELEMent<x> = 1 to 4
<NRf> = See the DL6000/DLM6000 User’s Manual.
Example
:GONOGO:TELECOMTEST:SELECT1:MASK:
ELEMENT1:SPCOUNT 1,2
:GONOGO:TELECOMTEST:SELECT1:MASK:
ELEMENT1:SPCOUNT? -> :GONOGO:
TELECOMTEST:SELECT1:MASK:ELEMENT1:
SPCOUNT 2.000E+00,1.000E+00
:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:WCOunt (Wave Count)
Function Sets the upper and lower limits of the number of
acquisitions for the element that results in error or
queries the current setting.
Syntax
:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:WCOunt {<NRf>,<NRf>}
:GONogo:TELecomtest:SELect<x>:MASK:
ELEMent<x>:WCOunt?
<x> of SELect<x> = 1 to 4
<x> of ELEMent<x> = 1 to 4
<NRf> = See the DL6000/DLM6000 User’s Manual.
Example
:GONOGO:TELECOMTEST:SELECT1:MASK:
ELEMENT1:WCOUNT 1,2
:GONOGO:TELECOMTEST:SELECT1:MASK:
ELEMENT1:WCOUNT? -> :GONOGO:
TELECOMTEST:SELECT1:MASK:ELEMENT1:
WCOUNT 2.000E+00,1.000E+00
:GONogo:ZPARameter?
Function Queries all settings related to zone/parameter
determination.
Syntax
:GONogo:ZPARameter?
:GONogo:ZPARameter:SELect<x>?
Function Queries all settings related to the condition of the
zone/parameter determination.
Syntax
:GONogo:ZPARameter:SELect<x>?
<x> = 1 to 4