2-4
IM AQ1300-01EN
Measurement Status Indications
The measurement status is indicated.
Status Name
Status Indication
Description
Tx time
The remaining Tx time/
number of frames
The remaining time is indicated in seconds.
The remaining number of frames is indicated
by a number from 0 to 99999999.
Statistic logging
STAT LOG (gray)
Statistic logging is stopped.
STAT LOG (blue)
Statistic logging is in progress.
Optical output off
control
LASER OFF (gray)
The laser is not off.
LASER OFF (red)
The laser is off.
LFS control
LFS Control (gray)
LF and RF signals are not being sent.
LFS Control (red)
LF and RF signals are being sent.
Summary
A summary of the settings is displayed, or the addresses are displayed.
• Summary: A summary of representative settings is displayed. For details, see section 2.2.
• Address: The source and destination MAC and IP addresses are displayed.
For information about switching between the summary and the address display, see section 7.6.
Remote Control Status Indications
The remote control status is indicated.
Except for the unconnected status, all the statuses are for when the test type is Auto(Remote).
Status Name
Status
Indication
Description
Unconnected
• A test type other than Auto(Remote) is selected.
Disconnected
-Master settings/results
• The test type is Auto(Remote).
• The remote control status is “disconnected.”
• The settings and results for the master are displayed.
Disconnected
-Slave settings/results
• The test type is Auto(Remote).
• The remote control status is “disconnected.”
• The settings and results for the slave are displayed.
Connected
No slave statistic errors
-Master control
• The test type is Auto(Remote).
• The remote control status is “connected.”
• The slave has no statistic errors.
• The settings, results, and controls are all for the master’s ports.
Connected
Slave statistic errors
-Master control
• The test type is Auto(Remote).
• The remote control status is “connected.”
• The slave has statistic errors.
• The settings, results, and controls are all for the master’s ports.
Connected
No slave statistic errors
-Slave control
• The test type is Auto(Remote).
• The remote control status is “connected.”
• The slave has no statistic errors.
• The settings, results, and controls are all for the slave’s ports.
Connected
Slave statistic errors
-Slave control
• The test type is Auto(Remote).
• The remote control status is “connected.”
• The slave has statistic errors.
• The settings, results, and controls are all for the slave’s ports.
Test Result Indications
Common Items
Pass/Fail Indication
This indication appears when the test type is Auto or Auto(Remote) and you have chosen to perform
pass/fail judgment.
• Pass: The results meet the requirements.
• Fail: The results do not meet the requirements.
2.1 Measurement Screens (Common Items)