02-4001-09 | Effective Date: May 29, 2018
Page-22
YES 45 FS/FI Storefront System
2”
2”
PM-1008-SS
FRAME INSTALLATION
6”
3/8”
Sealant
E1-1054 (E9-1038)
Flat Filler - Use At
All Anchor Locations
Detail 23
Detail 24
-For end load reactions over 500 lbs.,
attach the sill to the sill flashing using
PM-1008-SS screws.*
-Additionally, add one (1) PM-1008-SS
fastener 2” in both directions from the
centerline of the splice.
See
Detail 24
.
Anchoring of Sill Member to Sill Flashing
in the state of Florida is to be done per the
detail on the Florida Product Approval:
YES 45 FS - 8731
YES 45 FI - 7019.1
*To determine end load reactions,
consult YKK AP DirecTech or refer
to approved shop drawings
STEP 13
INSTALL FRAMES
-Snap in flat fillers, E1-1054, or 2-1/2” long
pieces of E9-1038 at head, jamb, anchor
locations.
-Prior to snapping the assemble frames
together, apply sealant to the interior snap
interface of the mullion, 6” up from the bottom.
-Apply sealant continuously to the front of the
back leg of the sill flashing and immediately set
the frame into the opening.
-Snap assembled frames together if using
screw spline assembly.
See
Detail 23
.
-Shim jamb and head members with a
minimum of 3/8” shim.
-Anchor the frame to the structure at the sill*,
head, and jamb: 3” from the ends and then
18” to 24” on center.
-Always install a shim at all anchor locations.
Note:
Use only flat head fasteners at head
and jamb conditions.
Содержание YES 45 FS
Страница 2: ......
Страница 35: ......
Страница 36: ...YKK AP America Inc 270 Riverside Parkway Suite 100 Austell Georgia 30168 www ykkap com...