02-4001-09 | Effective Date: May 29, 2018
Page-18
YES 45 FS/FI Storefront System
STEP 9
INSTALL SILL FLASHING
-Starting at the smallest opening height, install the sill flashing with a minimum of 3/8” shim
underneath. Sill flashing must be installed level.
-Anchor the sill flashing to the structure a maximum of 4” from each end and then
18” to 24” on center.
-Apply and tool sealant to cover the heads of all fasteners.
STEP 10
INSTALL SILL FLASHING SPLICE SLEEVE
-Remove the nub with a chisel or needle nose pliers a minimum length of 1-1/2”
as shown in
Detail 17
.
-After the sill flashing has been shimmed and installed to
the building structure, apply a small backer rod under the
sill flashing as shown in Detail 16.
-Position the Silicone Splice Sleeve against the back wall
below the groove.
-Bend the Silicone Splice Sleeve into the front on the
channel as shown. Mark, and cut the sleeve at this
position.
-Clean Sill Flashing and Silicone Splice Sleeve with iso-
propyl alcohol at the splice location
-Seal the flashing at the splice location as shown in
Detail 18
, before positioning the flashing. Set the
Silicone Splice Sleeve into the Silicone Splice Sleeve.
-Tool sealant tight as shown in
Detail 19
, squeezing the
sheet flat.
-Thoroughly seal the small joint directly in front of the
Silicone Splice Sleeve as shown in
Detail 19
.
FRAME INSTALLATION
1-1/2”
E2-0070
Splice Sleeve
(Trim to Fit)
Sealant
Detail 17
Sealant
Backer Rod Length
E2-0070
Splice Sleeve
Detail 18
When using E2-0070, a compatible
Silicone Sealant must be used at the
splice. Compatible Silicone Sealants
include Tremco Spectrum 2 and Dow
Corning 795.