INTRODUCTION 

The YELLOW JACKET H

2

 Hand-held Leak Detector features a long 

life, solid-state heated sensor technology that is designed to detect 

H

2

/Nitrogen Tracer Gas mixture 

The H

2

 Leak Detector does not require rechargeable batteries. When 

used with the H

2

/Nitrogen Tracer Gas mixture, the  H

2

 Leak Detector

will detect leak rates less than 5 ppm. This complies with standards 

EN35422  and  EN14624.  The  Tracer  Gas  mixture  complies  with 

Article 6, Paragraph 3 of EU Directive 2006/40/EC. 

FEATURES 

 H

2

 sensitivity <5 ppm  

 Uses 4 AA alkaline batteries 

 True mechanical pump 

 3 adjustable sensitivity levels 

 Automatic calibration and reset 

to ambient 

 Long life, stable sensor 

 Made in USA

 18 month warranty

 CE Certified

 Low battery indicator 

2

To order call 1-800-548-1191 or visit www.partdeal.com - [email protected]

Содержание 69341

Страница 1: ...Model 69341 Detects 5 H2 in 95 Nitrogen Tracer Gas H2 Tracer Gas Leak Detector Operations Manual To order call 1 800 548 1191 or visit www partdeal com info partdeal com ...

Страница 2: ...etector will detect leak rates less than 5 ppm This complies with standards EN35422 and EN14624 The Tracer Gas mixture complies with Article 6 Paragraph 3 of EU Directive 2006 40 EC FEATURES H2 sensitivity 5 ppm Uses 4 AA alkaline batteries True mechanical pump 3 adjustable sensitivity levels Automatic calibration and reset to ambient Long life stable sensor Made in USA 18 month warranty CE Certif...

Страница 3: ...e detector will sound a slow beep Warm up is usually less than 20 seconds 3 READY The detector is ready to begin searching for leaks when the the green Norm sensitivity LED turns on and the audio beep increases in frequency 2 Low Battery Indicator Sensitivity Level H2 Leak Detector Control Panel Low battery indicator Sensitivity level indicator Sensitivity adjust Power On Off 3 To order call 1 800...

Страница 4: ... the 4 AA Alkaline batteries when the red LED on the control panel is lit Follow battery installation instructions under Maintenance section Troubleshooting 4 To order call 1 800 548 1191 or visit www partdeal com info partdeal com ...

Страница 5: ...ector comes with a Leak Test Vial that allows the user to make sure the detector is performing properly To test 1 Remove the plastic seal cap on top of the Leak Test Vial by pulling it off see fig below 2 Turn on the detector and allow the unit to complete the warm up cycle 3 Place the sensor close to the small hole in the top of the Leak Test Vial The beep rate should increase indicating that the...

Страница 6: ...er supplied with the leak detector or they can be re ordered from your supplier or distributor Sensor Failure Mode If the sensor is not working correctly the H2 Leak Detector will not come out of the warm up mode If this happens first be sure the sensor is plugged in all the way If that does not correct the situation replace the sensor Sensor Replacement Remove sensor by pulling out of socket Inst...

Страница 7: ...rged into an empty system at a pressure of up to but not exceeding the rated system test pressure As Hydrogen is lighter than air always probe slightly above the suspected leak area Once the source of the leak is located and repaired the Tracer Gas can be released and the system can be recharged again with refrigerant Product Specifications Model 69341 H r o t c e t e D k a e L e m a N 2 Tracer Ga...

Страница 8: ...ce with the following instructions credit replace or repair at our option the defective leak detector provided it is returned within 18 months of the date of sale H2 Leak Detectors have a date of manufacture serial number located on the label on the bottom of the unit Correction in the manner provided above shall constitute a fulfillment of all liabilities with respect to the quality material and ...

Отзывы: