features accessible in the device settings menu (see Pages 22-23). The most influencing factor on
battery life is the backlight intensity, be sure to adjust the backlight level accordingly depending
on your current viewing conditions.
Charging the Battery:
To ensure maximum battery life, make sure the P51-870 TITAN® is charged
before and after each job session. To charge the device, remove the micro-
usb cover and connect the manifold to a power source via the provided data
transfer cable as pictured in Figure 11. When connected to a power source,
the LED will turn a solid green. It takes approximately 2.5 – 3hrs to reach full
charge from dead battery. Once the device has reached full charge, the
green LED will shut off indicating the charge is complete.
Operating the Backlight:
This instrument is equipped with an adjustable backlight and backlight auto dimming capabilities.
When the backlight dims during use, a touch anywhere on the screen or a quick press of the
power button can be used to wake up the device and power the backlight on.
To help conserve battery life, make sure to use the
backlight timer feature in device settings (Figure 12).
This feature allows the user to set intervals for how long
the backlight should remain on after the last user input.
The backlight timer can be adjusted from 5 seconds to
15 min. See page 22 for instructions on adjusting the
backlight level and timer.
Datalogging:
The P51-870 TITAN® digital manifold can be used to gather and record live system readings for
later analysis. From the moment the device is powered on, it begins to record all current data
inputs including Pressure, Temperature, and Vacuum. The logging rate can be adjusted anytime
through the device settings menu (see Page 22).