Administrator’s Guide for VP59/SIP-T58A/CP960 IP Phones
92
Permitted
Values
String within 32 characters
Default
var
Parameter static.security.user_password
<y0000000000xx>.cfg
Description
It configures the password.
The phone uses “user” as the default user password, "var" as the default var password and “admin” as
the default administrator password.
The valid value format is <username>:<new password>.
Example:
static.security.user_password = user:123 means setting the password of user to 123.
static.security.user_password = admin:456 means setting the password of administrator to 456.
static.security.user_password = var:789 means setting the password of var to 789.
Note: The phones support ASCII characters 32-126(0x20-0x7E) in passwords. You can set the pass-
word to be empty via the web user interface only.
Permitted
Values
String within 32 characters
Default
Blank
Web UI
Security > Password
Phone UI
Settings > Advanced Settings (default password: admin) > Set Password
Note: You cannot change the user password via the phone user interface.
User Access Level Configuration
For more information, refer to
Yealink SIP IP Phones Configuration Guide for User Access Level
.
The following table lists the parameters you can use to configure the user access level.
Parameter static.security.var_enable
[1]
<y0000000000xx>.cfg
Description It enables or disables the 3-level access permissions (admin, user, var).
Permitted
Values
0-Disabled
1-Enabled
Default
0
Parameter static.web_item_level.url
[1]
<y0000000000xx>.cfg
Description It configures the access URL of the file, which defines 3-level access permissions.
Permitted
Values
URL within 511 characters
Default
Blank
Parameter static.security.default_access_level
[1]
<y0000000000xx>.cfg
Description
It configures the default access level to access the phone user interface.
Note: It works only if “static.security.var_enable” is set to 1 (Enabled).
Permitted
Values
0-user
1-var
Содержание One Talk CP960
Страница 1: ......