4.2 Settings on Welding Source Panel
4-10
HW0480311
HW0480311
<Example>
When the parameter D1-11 is ON (enabled):
Press the button
"Record" for three seconds or more to save the changed values
(conditions). Do not turn OFF the welding source during saving conditions. When
the 7-segment LED indicators are lit again, the saving of conditions is completed.
4.2.6
Saving Welding Conditions
When the parameter set value is changed by the operations on the welding source panel, the
LED indicator lamp above the button
"Record" blinks.
The following describe how to save the settings.
(1) Referring to " 4.2.2 User Files ", specify the file number where the data are to be
saved.
(2) Press the button
"Record" for 3 seconds or more, and the 7-segment LED indica-
tors display dashes "- - -".
(3) When the saving is completed, the 7-segment LED indicators returns to the status
where the conditions were saved.
If the power supply is turned OFF while saving the welding conditions, the data can-
not be successfully saved. Confirm that the 7 segment LED indicators are lit again
before turning OFF the power supply.
• For P parameters, the changed data are validated at the same time the
change is made. However, when the welding type is changed or the
power supply switch of the welding source is turned OFF, the changed
data will be lost.
The changed data are overwritten on the data of the file where the data
are to be stored.
V
A
Wire m/min
Type
14
14
14
CAUTION
44/129