12
VS-616PS5 Installation & Quick Start Manual
General Specifications
Control Characteristics
Control Method
Sine Wave PWM, Flux Vector
Starting Torque
150% at 1% speed
Speed Control Range
100 : 1 (Constant Power Excluded)
Speed Control Accuracy
+/- 0.02%
Torque Limit
Independent Quadrant Settings 0 - 300%
Frequency Control Range
0.1 to 200 Hertz
Frequency Accuracy
Analog Speed Command 0.1% Digital Speed Command 0.01%
Frequency Setting Resolution
Digital Operator: 0.01 Hertz
Analog Reference: 0.03 Hertz @ 60 Hz
Output Frequency Resolution
0.01 Hertz
Frequency Setting Signals
0 to +10 VDC (20 Kohm)
0 to +/-10 VDC (20 Kohm)
4 to 20 mA (250 ohm)
Accel/Decel Time Setting
0 to 6000.0 seconds, independent ramps
Braking Torque
Approximately 100% with optional resistor braking
Protection Functions
Motor Overload Protection
UL Recognized Electronic Thermal Overload
Instantaneous Overcurrent
200% rated current, motor coasts to stop
Fuse Protection
Motor coasts to stop when fuse blows
Overload
Motor shuts off after 150% for 1 minute
Overvoltage
410 VDC (230VAC units) 820 VDC (460 VAC units)
Undervoltage
User adjustable value
Momentary Power Loss
TRIP after 15 ms continuous power loss
Heatsink Overheat
Thermistor Protection
Ground Fault
Electronic Overcurrent circuit
Power Charge Indicator
Charge LED ON above 50 VDC bus voltage
Phase Loss
Input/Output selectable power protection
Environmental Specifications
Location
Indoors, clean and dry
Ambient Temperature
Open Chassis: +14 to 113 °F (-10 to 45 °C)
NEMA 1: +14 to 104 °F (-10 to 40 °C)
Storage Temperature
-4 to 140 °F (-20 to 60 °C)
Humidity
95% Relative Humidity, non-condensing
Vibration
9.8 m/sec
2
(1G), less than 20 Hz // 1.96 m/sec
2
(0.2G) @ 20 to 50 Hz