background image

YASKAWA

MANUAL NO.  TOBP C730600 31A

Upon receipt of the product and prior to initial operation, read these instructions 
thoroughly and retain them for future reference.

MODEL: DI-16H2

DIGITAL SPEED REFERENCE CARD DI-16H2

Varispeed OPTION CARD

INSTRUCTIONS 

YASKAWA

Содержание Varispeed DI-16H2

Страница 1: ...31A Upon receipt of the product and prior to initial operation read these instructions thoroughly and retain them for future reference MODEL DI 16H2 DIGITAL SPEED REFERENCE CARD DI 16H2 Varispeed OPT...

Страница 2: ...liability is assumed with respect to the use of the information contained herein Moreover because Yaskawa is con stantly striving to improve its high quality products the information contained in this...

Страница 3: ...this manual may be indicated without covers or safety shields in order to show details Be sure to restore covers or shields before operating the Inverter and operate the Inverter according to the inst...

Страница 4: ...result in loss of life or seri ous injury Indicates precautions that if not heeded could result in relatively less serious or minor injury or damage to the equipment Failure to heed even a precaution...

Страница 5: ...icators have turned OFF The time is shown on the Inverter s front cover Failure to do so can result in electric shock Do not allow cables to be damaged subjected to stress placed under heavy objects o...

Страница 6: ...e However if the Yaskawa Authorized Service Center determines that the problem with a Yaskawa product is not due to defects in Yaskawa s workmanship or materials then the cus tomer will be responsible...

Страница 7: ...c power or under water use must contact their Yaskawa representatives or the nearest Yaskawa sales office beforehand This product has been manufactured under strict quality control guidelines However...

Страница 8: ...ames 10 4 Installation and Wiring 11 4 1 Installing the DI 16H2 on the Inverter 11 4 2 Connecting the Inverter Option Card and Peripherals 13 5 Precautions when Using Input Signals 15 6 External termi...

Страница 9: ...VS 676VG3 VH3 Set the first digit of Sn 04 run mode selection 1 to 0 Factory setting 1 Master speed selection should be selected for the option side Set the first digit of Sn 08 run mode selection 5...

Страница 10: ...4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 7 7 6 1 5 7 7 7 7 6 6 0 96 MI 0 2 0 External input terminal TB1 Co...

Страница 11: ...nserting the spacers on the control board into the spacer mount ing holes two holes of the DI 16H2 until hearing a click Refer to A in Fig 1 4 For VS 616H3 VS 676VG3 VH3 and VS616G5 series Inverters c...

Страница 12: ...control terminal E DI 16H2 DI 16H2 External terminal Control terminal Connector 2CN Spacer for option card two spacers Spacer mounting hole for option card two holes Sectional view seen from bottom 4C...

Страница 13: ...cuits from TB1 1 to TB1 16 are on the same circuit Fig 2 shows input circuit TB2 6 as an example 3 For VS 616H3 series Inverters the control terminal 32 on the control board is the ground terminal 4 F...

Страница 14: ...d VS 616G5 series Inverters connect the FG cable of the DI 16H2 to the ground connecting terminal 12 For Varispeed G7 F7 and Varispeed AC series Inverters connect the FG cable of the DI 16H2 to the In...

Страница 15: ...terminals 6 1 Functions The DI 16H2 is equipped with external terminals TB1 11 poles and TB2 8 poles for connect ing peripheral devices so that digital signals 16 bit binary 4 digit BCD signed signal...

Страница 16: ...nal block sign Pin No Input signal type 1 12 bit signed binary 16 bit signed binary 3 digit signed BCD 4 digit signed BCD 5 digit unsigned BCD S1 selection 12 bit S1 selection 16 bit S1 selection 12 b...

Страница 17: ...pen Close Open Close 5 ms or more 1 ms or more 5 ms or more 5 ms or more 1 ms or more 5 ms or more 40 ms or more 6 4 ms or more 10 ms or more Digital reference data TB1 1 to 8 TB2 1 to 8 and SIGN sign...

Страница 18: ...mly 3 Confirm that the terminal screws are thoroughly tightened so that the wire will not come loose Applicable wire core size 26 to 16 AWG Tightening torque 0 22 to 0 25 Nxm Fig 5 Sheath Strip Length...

Страница 19: ...r limit for setting range is set by the maximum frequency Cn 02 and the frequency ref erence upper limit Cn 14 Lower limit for setting range is set by the minimum frequency Cn 07 and the frequency ref...

Страница 20: ...ch S1 selection Reference input mode Reference setting range 1 Monitor U1 01 display units o1 03 F3 01 o1 13 0 1 o1 13 1 1 0 or 1 0 12 bit 1 digit BCD signed 1 110 to 110 0 01 Hz 0 01 16 bit 4 digit B...

Страница 21: ...Output frequency F is output in reference setting r min 1 o1 03 setting 120 3 Setting example of o1 03 If setting 12000 to o1 03 reference input at 100 is 2000 and monitor display is 200 0 40 to X999...

Страница 22: ...card Monitor Select Display Scaling o1 03 Frequency units of refer ence setting and monitor 0 to 39999 0 No 0 0 01 Hz 1 0 01 2 to 39 r min setting the number of motor poles 40 to 39999 Refer to Table...

Страница 23: ...le length of D7 and D8 has to be shorter than the other cables due to the input terminal allocation Conventional model DI 16H Conventional model DI 16H2 New model DI 16H2 Grounding lead Grounding lead...

Страница 24: ...30600 31A Published in Japan October 2008 07 12 Date of publication Date of original publication 1 Revision number Date of Publication Rev No Section Revised Content December 2007 First edition Octobe...

Страница 25: ...l Phone 55 11 3585 1100 Fax 55 11 5581 8795 YASKAWA ELECTRIC EUROPE GmbH Hauptstra e 185 65760 Eschborn Germany Phone 49 6196 569 300 Fax 49 6196 569 398 YASKAWA ELECTRIC UK LTD 1 Hunt Hill Orchardton...

Отзывы: