YASKAWA
TOEPC71061782C GA800 Drive Installation & Primary Operation
37
Figure 9.1 LED Flashing Statuses
Figure 9.2 Relation between RUN LED and Drive Operation
10
Drive Start-Up
1. Install and wire the drive.
2. Energize the drive.
3. Run the Setup Wizard to automatically set these functions:
•
Control Method Selection
•
HD/ND selection
•
Motor data
•
Frequency Reference
•
Run command source
•
Acceleration and Deceleration Times
4. Use
A1-06 [Application Preset]
to initialize the drive for a special application if necessary.
5. Run the motor without a load.
6. Make sure that the drive is operating correctly and make sure that the host controller is sending commands to the
drive.
7. Connect the load.
8. Run the motor.
9. Make sure that the drive is operating correctly.
10. Fine-tune and set application parameters, such as PID.
11. Do a final operation check and make sure that parameter settings are correct.
The drive is prepared to run the operation.
◆
Setup Wizard
Refer to the motor nameplate and record the information in this table before you energize the drive.
Item
Value
Motor Rated Power
kW
Motor Rated Voltage
V
Motor Rated Current (FLA)
A
Motor Rated Frequency
Hz
Motor Maximum Frequency
Hz
Motor Pole Count
Number of Motor Poles