32
YASKAWA
TOEPC71061782C GA800 Drive Installation & Primary Operation
Table 8.1 Keypad Components and Functions
Symbol
Name
Function
A
RUN LED
Illuminates to show that the drive is operating the motor.
The LED turns OFF when the drive stops.
Flashes to show that:
•
The drive is decelerating to stop.
•
The drive received a Run command with a frequency reference of 0 Hz, but the drive is not set for zero speed control.
Flashes quickly to show that:
•
The drive received a Run command from the MFDI terminals and is switching to REMOTE Mode while the drive is in LOCAL Mode.
•
The drive received a Run command from the MFDI terminals when the drive is not in Drive Mode.
•
The drive received a Fast Stop command.
•
The safety function shut off the drive output.
•
You pushed
on the keypad while the drive is operating in REMOTE Mode.
•
The drive is energized with an active Run command and
b1-17 = 0 [Run Command at Power Up = Disregard Existing RUN Command]
.
B
ALM LED
Illuminates when the drive detects a fault.
Flashes when the drive detects:
•
Alarm
•
Operation Errors
•
A fault or alarm during Auto-Tuning
The light turns off during regular drive operation. There are no alarms or faults.
C
microSD Card Slot
The insertion point for a microSD card.
D
Function Keys
F1, F2, F3
The menu shown on the keypad sets the functions for function keys.
The name of each function is in the lower half of the display window.
E
LO/RE LED
Illuminated: The keypad controls the Run command (LOCAL Mode).
OFF: The control circuit terminal or serial transmission device controls the Run command (REMOTE Mode).
Note:
•
LOCAL: Use the keypad to operate the drive. Use the keypad to enter Run/Stop commands and the frequency reference command.
•
REMOTE: Use the control circuit terminals or serial transmission to operate the drive. Use the frequency reference source entered in
b1-01
and the Run command source selected in
b1-02
.
F
LO/RE Selection Key
Switches drive control for the Run command and frequency reference between the keypad (LOCAL) and an external source (REMOTE).
Note:
•
The LOCAL/REMOTE Selection Key continuously stays enabled after the drive stops in Drive Mode. If the application must not
switch from REMOTE to LOCAL because it will have a negative effect on system performance, set
o2-01 = 0 [LO/RE Key Function
Selection = Disabled]
to disable
.
•
The drive will not switch between LOCAL and REMOTE when it is receiving a Run command from an external source.
G
STOP Key
Stops drive operation.
Note:
Push
to stop the motor. This will also apply when a Run command (REMOTE Mode) is active at an external Run command
source. To disable
priority, set
o2-02 = 0 [STOP Key Function Selection = Disabled]
.
H
Left Arrow Key
•
Moves the cursor to the left.
•
Goes back to the previous screen.
Up Arrow Key/Down Arrow
Key
/
•
Scrolls up or down to show the next item or the previous item.
•
Selects parameter numbers, and increments or decrements setting values.
Right Arrow Key (RESET)
•
Moves the cursor to the right.
•
Continues to the next screen.
•
Resets the drive to clear a fault.
ENTER Key
•
Enters parameter values and settings.
•
Selects menu items to move between keypad displays.
•
Selects each mode, parameter, and set value.
I
RUN Key
Starts the drive in LOCAL Mode.
Starts the operation in Auto-Tuning Mode.
Note:
Before you use the keypad to operate the motor, push
on the keypad to set the drive to LOCAL Mode.
J
USB Terminal
For factory adjustment
K
RJ-45 Connector
Connects to the drive using an RJ-45 8-pin straight through UTP CAT5e extension cable or keypad connector.