Installation and Operation Guide SOLECTRIA PVI 25TL-480-R
DOCR-071030-A (11/17/2020)
Page 79 of 101
1.Observe for 5 minutes and see whether the alarm will be eliminated
automatically;
2.Check for foreign objects on fan blades;
3.Switch off 3-phase work power supply and then reboot the system;
4.Contact after-sales service personnel
3. IntFanErr
Recommended solutions:
1.Observe for 5 minutes and see whether the alarm will be eliminated
automatically;
2.Check for foreign objects on fan blades;
3.Switch off 3-phase work power supply and then reboot the system;
4.Contact after-sales service personnel
WARN
Warn0030
(EepromErr)
Definition:
Internal alarm
Recommended solutions:
1.Observe for 5 minutes and see whether the alarm will stop
automatically;
2.Contact after-sales service personnel
Warn0040 (DC
SPD fault)
Recommended solutions:
The alarm is reserved now. The alarms in field can be ignored.
Warn0050
(TempSensorErr)
Recommended solutions:
1.Observe temperature display;
2.Switch off 3-phase working power supply and then reboot the
system;
3.Contact after-sales service personnel
Warn0100 (AC
SPD fault)
Recommended solutions:
The alarm is reserved now. The alarms in field can be ignored.
PROTECTION
Protect0090
Recommended solutions: