Installation and Operation Guide SOLECTRIA PVI 25TL-480-R
DOCR-071030-A (11/17/2020)
Page 16 of 101
Table 2-1 Shipment Box Contents
IDENTIFIER PART
QUANTITY DESCRIPTION
1
Power Head
1
Inverter Power Head, top
2
Wire-Box
1
Inverter Wire Box, bottom
3
Mounting Bracket Assembly
1
Mounting Bracket assembly, 1 piece
4
Accessory Kit
1
Necessary hardware and accessories for installation
A
M6 x 18mm Phillips Screw
12
4 for securing and bonding Wire-Box to Power Head; 6 for
securing the inverter to the mounting bracket; 1 for an
External Ground connection; 1 spare
B
6 Pin PCB Connector Plug
1
For RS485 Connection
C
2 Pin PCB Connector Plug
1
For Power Supply
D
Hex Socket Screw
1
Spare (for Wire-Box Cover)
E
FOMlink Wi-Fi Module
1
For access to HMI
3.
Installation
Before attempting to install the SOLECTRIA PVI 25TL-480-R
read Section 3 in its entirety.
WARNING
Read These Instructions:
Failure to follow these installation instructions may result in personal injury or death. Read this
section in its entirety before attempting to install a SOLECTRIA PVI 25TL-480-R.
NOTICE!
Improper Installation Will Void Warranty:
This section includes important information regarding the proper installation
environment and mechanical and electrical requirements. Failure to follow these instructions will void the warranty.
NOTICE!
Maintain NEMA 4X Rating:
Water ingress could result in unsafe conditions. Please take note of the following
recommendations in order to maintain the NEMA rating and prevent water from entering into the system.
Adding weep holes or any other holes will void the warranty.
All conduits must be sealed to prevent moisture ingress.
o
Sealing conduit entries at the PV array will provide additional protection. Firestop putty or electrically
rated conduit foam is recommended.
NOTICE!
Allowable Ambient Temperature Ranges:
Storage Temperatures: -40°C to 70°C, Inverter not installed and in storage (in packaging or unpackaged).
Normal Operating Temperatures: -30°C to 60°C, Inverter installed, connected to electric utility grid, and
operating during daylight hours.
Connected but Off Temperatures: No low temperature limit to 70°C, Inverter installed, connected to electric
utility grid but non-operating (daylight or nighttime hours).