Servo ON Command
Type
Name
Description
Servo ON
Incremental Encoder
The function is executed only once when
the command is sent. Then, motor will be
ready for operation.
Absolute Encoder
In the Pn587.0 = 1 setting, the function is
executed only once when the command is
sent. Then, motor will be ready for opera-
tion.
Servo OFF
Motor power is OFF.
Utility Function: Polarity Detection (Fn080)
This utility function is executed using Panel operator, Digital operator and S.
Parameter
Function
Default
Value
When ena-
bled
No.
Dig.
Pn481
Polarity Detection Speed Loop Gain [0.1 Hz]
400
Immediately
Pn482
Polarity Detection Speed Loop Integral Time
Constant [0.01 ms]
3000
Immediately
Pn486
Polarity Detection Reference Acceleration/
Deceleration Time [ms]
25
Immediately
Pn487
Polarity Detection Constant Speed Time [ms]
0
Immediately
Pn488
Polarity Detection Reference Waiting Time
[ms]
100
Immediately
Pn490
Polarity Detection Load Level [%]
100
Immediately
Pn493
Polarity Detection Command Speed [min
-1
]
50
Immediately
Pn494
Polarity Detection Range [0.001 rev]
0.250
Immediately
Pn495
Polarity Detection Confirmation Force Refer-
ence [%]
100
Immediately
Pn498
Polarity Detection Allowable Error Range
[deg.]
10
Immediately
Pn587
Polarity Detection Execution Selection for
Absolute Linear Encoder
-
-
0
0
Does not detect polarity
0
Immediately
1
Detects polarity
Parameter
Function
Default
Value
When ena-
bled
No.
Dig.
Pn481
Polarity Detection Speed Loop Gain [0.1 Hz]
400
Immediately
Pn482
Polarity Detection Speed Loop Integral Time
Constant [0.01 ms]
3000
Immediately
Pn485
Polarity Detection Reference Speed [mm/s]
20
Immediately
Execution of the Function
with MECHATROLINK and
Network Option Model
Related Parameters
(Rotary Motors)
Related Parameters
(Linear Motors)
Sigma-5 and Sigma-7 Series SERVOPACKs
SERVOPACK Set-up
Polarity Detection Functionality