Three-Phase 400 V Class Drive Models 4A0038 to 4A0165
Table A.5 Power Ratings Continued (Three-Phase 400 V Class)
Item
Specification
Drive Models
4A0038 4A0044 4A0058 4A0072 4A0088 4A0103 4A0139 4A0165
Maximum Applicable
Motor Capacity (HP)
ND Rating
25
30
40
50
60
75
100
125
Input
Input Current (A)
ND Rating
44
52
58
71
86
105
142
170
Rated Voltage
Rated Frequency
Three-phase: 380 to 480 Vac 50/60 Hz/510 to 680 Vdc
Allowable Voltage Fluctuation
-15 to 10%
Allowable Frequency Fluctuation
±5%
Input Power (kVA)
ND Rating
46.6
54.9
53.0
64.9
78.6
96.0
130
156
Output
Rated Output
Capacity (kVA)
ND Rating
29
34
44
55
67
78
106
126
Rated Output
Current (A)
ND Rating
38
44
58
72
88
103
139
165
Overload Tolerance
ND Rating: 120% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
Carrier Frequency
User-adjustable between 1 and 15 kHz
User-adjustable
between 1 and
10 kHz
Maximum Output Voltage (V)
Three-phase: 380 to 480 V (proportional to input voltage)
Maximum Output Frequency (Hz)
400 Hz (user-adjustable)
<3> DC is not available for UL/CE standards.
<4> Rated motor capacity is calculated with a rated output voltage of 440 V.
<5> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings
raise the carrier frequency and require current derating.
A.1 Power Ratings
174
YASKAWA ELECTRIC TOEP YAIP1U 01B YASKAWA AC Drive - P1000 Quick Start Guide
Содержание P1000