A-2
151521-1CD
151521-1CD
3.
Connect the limit switch Turck cables to the hard stop limit switches. Refer to system prints for
additional wiring information.
4.
Reset the soft limits to appropriate values. Refer to Concurrent I/O and Parameters manual for
instructions for resetting soft limits.
A.2
Installing the Zone Ring
To install the optional zone ring, proceed as follows:
1.
Remove the adaptor plate and brake wear plate to provide access to the drive frame.
2.
Install the limit switch mounting brackets directly to the drive frame using the M6x20 hardware
provided (see Figure 22 for standard configuration).
3.
Mount the J-box and mounting plate directly to drive frame using M6x20 hardware provided.
Fig. A-3 Zone Ring
4.
Connect limit switch cables to the J-box module. Refer to system prints for additional wiring
information.
ZONE A
ZONE B
ZONE A+B
38 of 47