manualshive.com logo in svg
background image

8 Specifications

YASKAWA ELECTRIC

SIEP YEUOCL1 01A CANopen-Lift Communication Option Installation Manual

17

Minor Faults/Alarms

This section gives information about the causes and possible solutions when a minor fault or alarm occurs. Use
the information in this table to remove the cause of the minor fault or alarm.

Code

Name

Causes

Possible Solutions

AEr

Station Address Setting
Error

Option card node address is outside of
the acceptable setting range.

For CANopen communication, set

F6-35

[CANopen Node ID Selection]

correctly.

CALL

Serial Comm Transmission
Error

The communications cable wiring is
incorrect.

Correct any wiring errors.

There is a short circuit or the
communications cable is not connected.

Repair short circuits and connect cables.

Replace the defective communications cable.

There was a programming error on the
controller side.

Examine communications at start-up and correct
programming errors.

The communications circuitry is
damaged.

Do a self-diagnostics check.

If the problem continues, replace the control
board or the drive. For information about
replacing the control board, contact Yaskawa or
your nearest sales representative.

The termination resistor setting for
MEMOBUS/Modbus communications
is incorrect.

On the last drive in a MEMOBUS/Modbus
network, set DIP switch S2 to the ON position to
enable the termination resistor.

EEP

EEPROM Checksum Error

Communication wiring is faulty, there is
a short circuit, or something is not
connected properly.

Correct any wiring errors.

EEPROM checksum error.

If these errors occur, the object dictionary will be
reset to its default values. After the object
dictionary has been changed and object
dictionary contents are then changed, execute a
Store Parameter command (Index = 1010 (Hex)).

If the object dictionary has not been changed,
execute a Restore Parameter command (Index =
1011 (Hex)).

Programming error occurred on the
controller side.

Check communications at start-up and correct
programming errors.

Communications circuitry is damaged.

Perform a self-diagnostics check.

If the problem continues, replace either the
control board or the entire drive. For instructions
on replacing the control board, contact Yaskawa
or your nearest sales representative.

8

Specifications

Item

Specification

Model

SI-L3

Communication Profile

CiA-301 Ver. 4.02
CiA-417 Ver. 2.2.0, Profile Velocity and Profile Position

Connector

9 pin D-sub connector

Communication Speed

10 kbps to 1 Mbps

Ambient Temperature

-10 °C to +50 °C

Humidity

up to 95% RH (non-condensing)

Storage Temperature

-20 °C to +60 °C

Area of Use

Indoor (free of corrosive gas, airborne particles, etc.)

Altitude

Up to 1000 m

Содержание L1000A Series

Страница 1: ...MANUAL NO SIEP YEUOCL1 01A CANopen Lift Communication Option Communication Option Card for Lift Inverter Drive YASKAWA L1000A Installation Manual Type SI L3...

Страница 2: ...This Page Intentionally Blank 2 YASKAWA ELECTRIC SIEP YEUOCL1 01A CANopen Lift Communication Option Installation Manual...

Страница 3: ...cable Models 8 3 Receiving 8 Receiving the Option Card 8 Content and Packaging 8 Tools Required 8 4 CANopen Lift Option Components 9 CANopen Lift Option SI L3 9 CANopen Lift Option Status LEDs 9 RUN L...

Страница 4: ...4 YASKAWA ELECTRIC SIEP YEUOCL1 01A CANopen Lift Communication Option Installation Manual 8 Specifications 17 Revision History 18...

Страница 5: ...B Printed Circuit Board FCS Frame Check Sequence INVR MEMOBUS register number EDS Electronic Data Sheet file About Registered Trademarks CANopen is a registered Community Trademark of CAN in Automatio...

Страница 6: ...lothing and remove all metal objects such as watches or rings Failure to obey can cause death or serious injury WARNING Electrical Shock Hazard The leakage current of the drive will be more than 3 5 m...

Страница 7: ...Make sure that all connections are correct after you install the drive and connecting peripheral devices Failure to obey can cause damage to the drive Intended Use This communication option card is e...

Страница 8: ...ns Make sure to read and understand the safety information and precautions before using the product Receiving the Option Card Please perform the following tasks after receiving the Communication Optio...

Страница 9: ...ANopen Lift Option has two LEDs that indicate the communication status RUN LED LED Color Display Meaning RUN Green On The device is in Operational State Green Blinking The device is in Pre Operational...

Страница 10: ...e Communication Option card is connected to the network using a 9 pin D sub connector flickering on 50 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200...

Страница 11: ...option card to the network using a 9 pin D sub connector wired like shown below Figure 4 3 Wiring Diagram Note The FE terminal on the Communication Option must be connected to the drive ground termin...

Страница 12: ...will void warranty Yaskawa is not responsible for changes to the product made by the user WARNING Fire Hazard Tighten all terminal screws to the correct tightening torque Connections that are too loos...

Страница 13: ...or I LED labels J Front cover Figure 5 1 Installing the Option Card 5 Prepare the 9 pin D sub network cable connectors For inverter drives CIMR Lx4F0002 to 0023 the network cable should be routed to t...

Страница 14: ...equency Reference Selection Selects the frequency reference input source 0 Operator Digital preset speed d1 01 to d1 17 1 Terminals Analog input terminals 2 MEMOBUS Modbus communications 3 Option card...

Страница 15: ...on Channel 1 Memobus Modbus 3 DCP 3 4 DCP 4 5 CANopen Lift 1 o1 03 Digital Operator Display Selection Sets the units to display the frequency reference and output frequency 0 0 01 Hz 1 0 01 100 E1 04...

Страница 16: ...option card connected to connector CN5 A is not compatible Connect the option card to the correct connector Note Encoder option cards are not compatible with connector CN5 A oFA01 Option Fault Connect...

Страница 17: ...mmunications is incorrect On the last drive in a MEMOBUS Modbus network set DIP switch S2 to the ON position to enable the termination resistor EEP EEPROM Checksum Error Communication wiring is faulty...

Страница 18: ...18 YASKAWA ELECTRIC SIEP YEUOCL1 01A CANopen Lift Communication Option Installation Manual Revision History Date of Publication Revision Number Section Revised Content November 2017 First Edition...

Страница 19: ...YASKAWA ELECTRIC SIEP YEUOCL1 01A CANopen Lift Communication Option Installation Manual 19...

Страница 20: ...that may apply Specifications are subject to change without notice for ongoing product modifications and improvements 2017 YASKAWA Europe GmbH YASKAWA Europe GmbH MANUAL NO SIEP YEUOCL1 01A 1 0 Publi...

Отзывы: