8 Monitor Displays (Un
)
8.6.3 Safety Input Signal Display Example
8-10
8.6.3
Safety Input Signal Display Example
Safety input signals are displayed as shown below.
• When the /HWBB1 signal turns OFF to activate the HWBB function
8.7
Monitor Display at Power ON
When Un number is set using Pn52F, the data of Un
that was specified in the panel operator is displayed
when the power is turned ON.
When 0FFF is set (factory setting), the status display mode (bb, run) is selected at power ON.
The bottom segment of
the number 1 is lit.
7 6 5 4 3 2 1
8
Analog
Pn52F
Monitor Display at Power ON
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
0000 to 0FFF
−
0FFF
Immediately
Setup
Speed
Position
Torque