![YASKAWA CIMR-ACA Series Скачать руководство пользователя страница 200](http://html1.mh-extra.com/html/yaskawa/cimr-aca-series/cimr-aca-series_instruction-manual_907553200.webp)
Machine Protection
6-
39
Reduction Ratio of Carrier Frequency and Rated Current
The following table shows the reduction ratio of the carrier frequency and rated current.
Model: CIMR-ACA25P5, 2011, 2022, 2045, 45P5, 4011, 4045, and 4075
*
* Under development.
Model: CIMR-ACA4022
Note: 100% means the rated output current value of the MxC.
Carrier Frequency
(kHz)
Continuous Rating 60-second Rating
4
100%
150%
8
90%
135%
12
80%
120%
Carrier Frequency
(kHz)
Continuous Rating 60-second Rating
4
100%
150%
8
80%
120%
12
60%
90%