5
-28
* 1. The default depends on the MxC capacity. The value for a 200 V class MxC of 5.5 kW is given.
* 2. The setting range is from 10% to 200% of the MxC rated output current. The value for a 200 V class MxC for 5.5 kW is given.
* 3. If a multi-function input is set for motor 2 (H1-
= 16), the setting range will depend upon the MxC capacity. The value for a 200 V class MxC of 5.5 kW is
given.
E4-04
Motor 2 Number
of Poles
Sets the number of poles of motor 2. This
value is automatically set during Auto-
Tuning.
2 to 48 4 poles
No
No
No
A
324H
-
Number of Poles
E4-05
Motor 2 Line-to-
Line Resistance
Sets the phase-to-phase resistance of
motor 2 in ohms. This value is automati-
cally set by the Auto-Tuning.
0.000 to
65.000
0.399
Ω
*1
No
A
A
A
325H
-
Term Resistance
E4-06
Motor 2 Leakage
Inductance
Sets the voltage drop due to motor leak-
age inductance as a percentage of rated
voltage of motor 2. This value is automat-
ically set during Auto-Tuning.
0.0 to
40.0
18.2%
*1
No
No
A
A
326H
-
Leak Inductance
E4-07
Motor 2 Rated
Output
Sets the rated power of motor 2 in kilo-
watts (kW). This value is automatically
set during Auto-Tuning.
5.50 to
650.00
5.50
kW
*1
No
A
A
A
327H
-
Mtr Rated Power
Parameter
Number
Name
Description
Setting
Range
Default
Change
during
Run
Control
Methods
MEMO-
BUS
Register
Page
Display
V/f
Open
Loop
Vector
Flux
Vector