![YASKAWA CIMR-ACA Series Скачать руководство пользователя страница 160](http://html1.mh-extra.com/html/yaskawa/cimr-aca-series/cimr-aca-series_instruction-manual_907553160.webp)
5
-64
Default Settings that Change with the Control Method (A1-02)
The defaults of the following parameters will change if the control method (A1-02) is changed.
Parameter
Number
Name
Setting Range
Unit
Default
Display
V/f
Control
Open loop
Vector
Flux
Vector
b3-01
Speed Search Selection
0 to 3
1
0
0
-
SpdSrch at Start
b3-02
Speed Search Deactivation Current
0 to 200
1%
120
100
-
SpdSrch Current
C3-01
Slip Compensation Gain
0.0 to 2.5
0.1
0.0
1.0
1.0
Slip Comp Gain
C3-02
Slip Compensation Primary Delay Time
0 to 10000
1 ms
2000
200
-
Slip Comp Time
C4-02
Torque Compensation Primary Delay Time
0 to 10000
1 ms
200
100
-
Torq Comp Time
C5-01
ASR Proportional Gain 1
0.00 to 300.00
0.01
-
-
20.00
ASR P Gain 1
C5-02
ASR Integral Time 1
0.000 to 10.000
0.001sec
-
-
0.500
ASR I Time 1
C5-03
ASR Proportional Gain 2
0.00 to 300.00
0.01
-
-
20.00
ASR P Gain 2
C5-04
ASR Integral Time 2
0.000 to 10.000
0.001 s
-
-
0.500
ASR I Time 2
C5-06
ASR Primary Delay Time Constant
0.000 to 0.500
0.001 s
-
-
0.004
ASR Delay Time
d5-02
Torque Reference Delay Time
0 to 1000
1 ms
-
-
0
Torq Ref Filter
n5-01
Feed Forward Control Selection
0 or 1
-
-
-
0
Feedfoward Sel
E1-04
E3-02
Maximum Output Frequency
0.0 to 120.0
0.1 Hz
60.0
*2
60.0
60.0
Max Frequency
E1-05
E3-03
Maximum Output Voltage
0.0 to 255.0
(0.0 to 510.0)
0.1 V
200.0
*2
200.0
200.0
Max Voltage
E1-06
E3-04
Base Frequency
0.0 to 120.0
0.1 Hz
60.0
*2
60.0
60.0
Base Frequency
E1-07
E3-05
Mid Output Frequency A
0.0 to 120.0
0.1 Hz
3.0
*2
3.0
0.0
Mid Frequency A
E1-08
E3-06
Mid Output Voltage A
0.0 to 255.0
(0.0 to 510.0)
0.1 V
14.0
*2
13.0
0.0
Mid Voltage A
E1-09
E3-07
Minimum Output Frequency
0.0 to 120.0
0.1 Hz
1.5
*2
0.5
0.0
Min Frequency
E1-10
E3-08
Minimum Output Voltage
0.0 to 255.0
(0.0 to 510.0)
0.1 V
7.0
*2
2.5
0.0
Min Voltage