SAFETY
8
YDG Operation Manual
NOTICE
If you remove battery from generator, insulate the
terminal on the end of the red, positive (+) battery
cable. If the terminal is not insulated, it may spark
when generator runs. Sparks may cause damage
to the generator's electronic circuits
Never operate the generator if it vibrates at high
levels, if engine speed changes greatly or if the
engine misfires often.
Never use an engine starting aid such as ether.
Engine damage will result.
Always make sure the generator is operated on a
level surface. If operated at an angle greater than
20° (in any direction) the battery could leak fluid.
The generator must be on a flat level surface when
checking the battery fluid level. If an engine runs for
short periods of time (less than three minutes) at an
angle greater than 25° in any direction, engine oil
may enter the combustion chamber causing
excessive engine speed and generate white
smoke. This may cause serious engine damage.
Always run the engine at full speed. Never run
engine at lower speeds. At full speed, the engine
runs at 3000 (or 3600) min
-1
(rpm) under load. The
engine must maintain 3000 (or 3600) min
-1
(rpm)
for generator to create correct voltage. Running
engine at lower speeds will damage generator and
powered items.
Never attach tools or appliances to the generator
before it is started. Always disconnect tools and
appliances from the generator before starting.
NOTICE
Observe the following environmental operating
conditions to maintain engine performance and
avoid premature engine wear:
• The standard range of ambient temperatures for
the normal operation of YANMAR engines is from
+5 °F (-15 °C) to +113 °F (+35 °C).
• If the ambient temperature e113 °F (+35
°C) the engine may overheat and cause the
engine oil to break down.
• If the ambient temperature is below +5 °F (-15 °C)
the engine will be hard to start and the engine oil
may not flow easily.
Contact your authorized YANMAR industrial engine
dealer or distributor if the engine will be operated
outside of this standard temperature range.
Observe the following environmental operating
conditions to maintain generator set performance
and avoid premature engine wear:
• Avoid operating in extremely dusty conditions.
• Avoid operating in the presence of chemical
gases or fumes.
• Avoid operating in a corrosive atmosphere such
as salt water spray.
Any part which is found defective as a result of
inspection or any part whose measured value does
not satisfy the standard or limit must be replaced.
Always tighten components to the specified torque.
Loose parts can cause equipment damage or
cause it to operate improperly.
Only use replacement parts specified. Other
replacement parts may affect warranty coverage.
Содержание YDG Series
Страница 10: ...INTRODUCTION viii YDG Operation Manual This Page Intentionally Left Blank ...
Страница 14: ...TABLE OF CONTENTS xii YDG Operation Manual This Page Intentionally Left Blank ...
Страница 36: ...PRODUCT OVERVIEW 22 YDG Operation Manual This Page Intentionally Left Blank ...
Страница 56: ...GENERATOR OPERATION 42 YDG Operation Manual This Page Intentionally Left Blank ...
Страница 82: ...TROUBLESHOOTING 68 YDG Operation Manual This Page Intentionally Left Blank ...
Страница 92: ...YIYDG EN0000 2021 10 YANMAR ITALY S p A http www yanmaritaly it ...