![Yamato VFK2560-8 Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/yamato/vfk2560-8/vfk2560-8_instruction-manual_905404042.webp)
35
VFK2560-8
6.9 Back-and-forth position of needle and looper
Fig. 6-23
Adjust so that the looper ① tip makes 0 - 0.05 ㎜ contact
with the needle ② when the looper ① is moved from the
far right to the left and its tip meets to the center of the
right needle.
This adjustment is done after loosening the screw ③ .
Fig. 6-24
③
0 - 0.05 ㎜
6. Adjustments
①
②
①
②
Содержание VFK2560-8