6.2 Top cover thread tension
6. Adjustments
①
②
③
1.0 ㎜
①
②
Fig. 6-4
Needle thread guide:
Make the distance between the center of the eye in the
needle thread take-up ② and the top of the needle thread
guide ① to 1.0 ㎜ when the needle thread take-up ② is at
the lowest point as standard.
Loosen the screw ③ to adjust it ① .
● To make the needle thread loop larger or when using
stretchable thread, raise the needle thread guide ① .
● To make the loop smaller, lower the needle thread guide
① .
Fig. 6-5
The standard position of the top cover thread eyelet (upper)
④ is the position where the top cover thread, which
passes through the top cover thread eyelet (upper) ④ and
top cover thread eyelet (lower) ⑥ , touches the right edge
of the slot of the top cover thread take-up ⑤ without
bending when the top cover thread take-up ⑤ has reached
the far right.
● When the top cover thread eyelet (upper) ④ is moved
to the right, the take-up amount increases.
● When the top cover thread eyelet (upper) ④ is moved
to the left, the take-up amount reduces.
Loosen the screw ⑦ to perform this adjustment.
The standard position of the top cover thread eyelet (upper)
④ is at its lowest position.
If the take-up amount is too much even after the above
adjustment has been performed, raise the top cover thread
eyelet (upper) ④ .
Loosen the screw ⑧ to perform this adjustment.
④
⑦
⑧
⑤
⑤
⑥
thread