6.12 Metering device (VF2404, 2504)
6.12.2 Setting tape guide
6.12.1 Presser foot tape guide
(1) Set the tape guide bar(long) ③ to a low position enough
for sewing.
(2) Set the inside of the tape guide, c. set ④ along “A” on
the presser foot tape guide ① . Set the tape guide ⑤
to guide a tape smoothly depending on a tape width.
(3) After positioning the tape guide bar(long) ③ , loosen
the screw ⑥ to position the tape guide stopper ⑦ . It
prevents the needle bar from touching the tape guide,
c. set ④ and makes the position of the tape guide
bar(long) ③ .
Set the presser foot tape guide ① depending on the needle
distance and a part to be sewn on a tape.
Loosen the screw ② to adjust it.
Before adjusting, ALWAYS turn the motor switch OFF and check that the motor has already stopped.