38
6. MAINTENANCE PROCEDURES
Accumulated Volume Hour Reset
Replacing items and resetting volume hours before notification is generated
①
Turn the ELB
“ON(
|
)
”.
②
Press POWER.
③
Pressing
and
holding
CLR
brings
up
in water quality display and unit
enters wear item reset mode.
④
Each time UNIT is pressed, indicators can be
toggled through in the information display as
follows.
→
→
⑤
Select item to be replaced, press and hold
CLR (acceptance tone will sound) to reset
cumulated water volume hours for that item.
Normal operation can be resumed. To exit
reset mode without resetting, press and hold
UNIT to resume normal operation.
* Reset the volume hours ONLY after item has been replaced. Be advised that cumulated volume
hours cannot be restored once they have been reset.
* Use the above procedure for replacing wear items which show time-related deterioration before
a replacement notification is generated.
Cartridge/filter replacement, according to the following intervals is recommended to maintain
consistent water quality, regardless of replacement alerts.
Membrane filter
Yearly
pre-process cartridge
Yearly
ion exchange resin (CPC-T) cartridge Yearly
Reverse Osmosis (RO) membrane
Every 2 years
②
③
⑤
⑥
Содержание Pure Line WE200
Страница 50: ...48 11 WIRING DIAGRAM ...