3 - 62
CHK
ADJ
CHECKING AND CHARGING THE BATTERY
Charging method using a constant voltage charger
Measure the open-circuit
voltage prior to charging.
Connect a charger and
AMP meter to the battery
and start charging.
NO
YES
Make sure that the current
is higher than the standard
charging current written on
the battery.
Charge the battery until the battery’s
charging voltage is 15 V.
Measure the battery open-circuit volt-
age after leaving the battery unused for
more than 30 minutes.
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
This type of battery charger cannot
charge the MF battery. A variable
voltage charger is recommended.
Voltage should be measured 30
minutes after the machine is
stopped.
NOTE:
Set the charging time at 20 hours
(maximum).
NOTE:
Charger
AMP meter
Volt meter
Содержание YZF-R1P 2001-2003
Страница 1: ......
Страница 2: ......
Страница 3: ...YZF R1P YZF R1PC SERVICEMANUAL LIT 11616 15 47 5PW 28197 10...
Страница 4: ......
Страница 9: ......
Страница 75: ...2 25 SPEC COOLING SYSTEM DIAGRAMS EAS00033 COOLING SYSTEM DIAGRAMS 1 Radiator fan 2 Radiator 3 Water pump...
Страница 77: ...2 27 SPEC COOLING SYSTEM DIAGRAMS 1 Water pump 2 Radiator cap 3 Thermostat 4 Thermostat housing...
Страница 78: ...2 28 SPEC COOLING SYSTEM DIAGRAMS 1 Radiator...
Страница 83: ...2 33 SPEC LUBRICATION DIAGRAMS 1 Main axle 2 Oil delivery pipe 3 Drive axle...
Страница 84: ...2 34 SPEC LUBRICATION DIAGRAMS 1 Cylinder head 2 Crankshaft...
Страница 439: ...YAMAHA MOTOR CO LTD 2500 SHINGAI IWATA SHIZUOKA JAPAN PRINTED IN U S A...