8-10
–
+
ELEC
E
ELECTRICAL COMPONENTS ANALYSIS
ELECTRICAL COMPONENTS
ANALYSIS
8
DIGITAL CIRCUIT TESTER
8
NOTE:
“
” indicates a continuity of electric-
ity which means a closed circuit at the
respective switch position.
Digital tester
J-39299 / 90890-06752
8090
MEASURING THE PEAK VOLTAGE
8
NOTE:
• When checking the condition of the igni-
tion system it is useful to know the peak
voltage.
• Cranking speed is dependant on many
factors (e.g., fouled or weak spark plugs, a
weak battery). If one of these is defective,
the peak voltage will be lower than speci-
fication.
• If the peak voltage measurement is not
within specification the engine will not
operate properly.
PEAK VOLTAGE ADAPTOR
8
NOTE:
The peak voltage adaptor should be used
with the digital circuit tester.
Peak voltage adaptor
YU-39991 / 90890-03169
8100
Содержание SX150C
Страница 1: ...SX150C VX150C DX150C SX200C SERVICE MANUAL 67H 28197 1F 11 LIT 18616 02 80 LIT186160280...
Страница 52: ...3 19 E INSP ADJ GENERAL LUBRICATION POINTS 3 Apply Water resistant grease 3290 3300 3310 3320 3330...
Страница 61: ...4 7 FUEL E FUEL INJECTORS INSPECTING THE FILTERS Check Filter Damage tears Replace Contaminants Clean 4040...
Страница 329: ...YAMAHA MOTOR CORPORATION USA Printed in USA Jan 2004 0 0 1 CR E...