(11)@MOVF <point number>,<DI number>,<DI status>
This command moves the robot toward a position specified by a point number until a specified DI
input condition is met. When the DI condition is met, the robot stops and the command termi-
nates. Even if the DI condition is not met, the command terminates when the target point is reached.
Point number
: This is a number assigned to each point (position data) and can
be from 0 to 999 (a total of 1,000 points). Data for the point
numbers can be edited with the @WRITE PNT statement. The
point variable "P" can also be used.
DI number
: Specify one of the general-purpose inputs DI0 to DI7.
DI status
: Specify 1 (ON) or 0 (OFF) as the input condition.
Transmission example
: @MOVF 2,10,l c/r l/f ................... Moves to point 2 until DI10
becomes 1 (ON).
Response example
: OK c/r l/f
c
CAUTION
The movement speed is set with PRM9 (MOVF speed) and independent of the PRM30 setting (Maximum
program speed).
(12)@DO <general-purpose output or memory output number>,<output status>
Turns a general-purpose output or memory output on or off.
Output number
: Specify one of the general-purpose outputs from 0 to 4 (5 points)
or one of the memory outputs from 100 to 131 (32 points).
Output status
: Specify 1 (ON) or 0 (OFF).
Transmission example
: @DO 3,1 c/r l/f ............................. Turns on general-purpose
output 3.
Response example
: OK c/r l/f
(13)@WAIT <general-purpose input or memory input number>,<input status>
Waits until a specified general-purpose input or memory input is switched to a specified status.
Input number
: Specify one of the general-purpose inputs from 0 to 7 (8 points)
or one of the memory inputs from 100 to 147 (48 points).
Input status
: Specify 1 (ON) or 0 (OFF).
Transmission example
: @WAIT l,l c/r l/f .......................... Waits until DI1 becomes 1
(ON).
Response example
: OK c/r l/f
(14)@TIMR <time>
Waits a specified amount of time.
Time
: Set the time between 1 and 65535 in units of 10ms.
Transmission example
: @TIMR 100 c/r l/f ....................... Waits one second.
Response example
: OK c/r l/f
Содержание SRCP
Страница 1: ...User s Manual ENGLISH E YAMAHA SINGLE AXIS ROBOT CONTROLLER E84 Ver 2 04 SRCP ...
Страница 2: ......
Страница 8: ...vi MEMO ...
Страница 18: ...1 10 MEMO ...
Страница 28: ...2 10 MEMO ...
Страница 132: ...8 34 MEMO ...
Страница 146: ...9 14 MEMO ...
Страница 176: ...10 30 MEMO ...
Страница 218: ...12 10 MEMO ...
Страница 235: ...15 1 15 SPECIFICATIONS Chapter 15 SPECIFICATIONS ...
Страница 240: ...MEMO 15 6 ...
Страница 241: ...16 1 16 APPENDIX Chapter 16 APPENDIX ...
Страница 245: ...MEMO ...