10-
28
10
OTHER OPERA
TIONS
10-8 Using the internal flash ROM
10-8-3 Initializing the flash ROM data
n
NOTE
The internal flash ROM can be used when the SRCP controller version is 24.10 or later and the TPB version is
12.51 or later.
1) On the initial screen, press
F3
(SYS).
[MENU]
select menu
1EDIT2OPRT3SYS
4MON
1PRM 2B.UP3INIT
4next
[SYS]
select menu
[SYS-B.UP]
select menu
1CARD2FROM
2LOAD3INIT
[SYS-B.UP-FROM]
FROM : 04.03.01
auto load : Invalid
1SAVE
[FROM-INIT]
initializing ...
2no
1yes
[FROM-INIT]
initialize OK ?
[FROM-INIT]
press EMG.button
2) Next, press
F2
(B.UP).
3) Press
F2
(FROM).
4) The ID number and auto load function setting
in the flash ROM appear on the screen.
Press
F3
(INIT) here.
5) Following the message, press the emergency
stop button on the TPB.
6) A confirmation message appears asking
whether to initialize the flash ROM data.
To initialize the flash ROM, press
F1
(yes).
To cancel, press
F2
(no).
7) This screen is displayed during initialization.
Содержание SRCP
Страница 1: ...User s Manual ENGLISH E YAMAHA SINGLE AXIS ROBOT CONTROLLER E84 Ver 2 04 SRCP ...
Страница 2: ......
Страница 8: ...vi MEMO ...
Страница 18: ...1 10 MEMO ...
Страница 28: ...2 10 MEMO ...
Страница 132: ...8 34 MEMO ...
Страница 146: ...9 14 MEMO ...
Страница 176: ...10 30 MEMO ...
Страница 218: ...12 10 MEMO ...
Страница 235: ...15 1 15 SPECIFICATIONS Chapter 15 SPECIFICATIONS ...
Страница 240: ...MEMO 15 6 ...
Страница 241: ...16 1 16 APPENDIX Chapter 16 APPENDIX ...
Страница 245: ...MEMO ...