38
En
Optimizing the speaker setting for your listening room (YPAO)
3
Place the optimizer microphone at your
normal listening position on a flat level
surface with the omni-directional
microphone heading upward.
y
It is recommended that you use a tripod (etc.) to affix the
optimizer microphone at the same height as your ears would
be when you are seated in your listening position. You can
use the attached screw of a tripod (etc.) to fix the optimizer
microphone to the tripod (etc.).
4
Press
4
ENTER
to start the setup
procedure.
This unit starts the automatic setup procedure
immediately. Loud test tones are output from each
speaker during the automatic setup procedure. During
the setup procedure, “Measuring...” appears in the
GUI screen.
• During the automatic setup procedure, do not perform any
operation on this unit.
• We recommend that you get out of the room while this unit
is in the automatic setup procedure. Keep quiet when you
leave the room. The necessary time for the automatic setup
procedure may differ depending on the environment of the
listening room and connected speakers (from 30 seconds
to 3 minutes).
y
To stop the automatic setup procedure and set this unit to the
pause mode, press one of the cursor buttons (
4
k
/
n
/
l
/
h
) or
4
ENTER
. In the pause mode, press
4
k
to retry the
procedure, and
4
l
to cancel the Auto Setup procedure.
5
Once all items are set successfully, following
display appears in the GUI screen.
• Press
4
n
and select “Setup” to set the measured
values.
• Press
4
k
and select “Retry” to retry the automatic
setup procedure. This unit starts the automatic
setup procedure immediately again.
• Press
4
h
and select “Detail” to view information
about measurement results and warning messages.
In the information display, press
4
k
/
n
repeatedly to toggle between the parameters. For
more details about warning messages, see the
“Auto Setup” section in “Troubleshooting” on
page 132.
• Press
4
l
and select “Exit” to exit from the Auto
Setup procedure. If you select “Exit”, “Don’t
Setup?” appears on the screen. To set the measured
values and exit, select “Setup”. To cancel the
settings and exit, select “Cancel”.
y
If you are not satisfied with the results or want to manually
adjust each parameter, set the parameters in “Basic” (see
page 88).
• If you change speakers, speaker positions, or the layout of
your listening environment, run “Auto Setup” again to
recalibrate your system.
• The distances displayed in the “Distance” results may be
longer than the actual distance depending on the
characteristics of your subwoofer or external amplifiers if
you connect them.
• In the “Equalizing” results, different values may be set for
the same band to provide finer adjustments.
Before proceeding next operation
Once you perform the next operation, this unit starts
the automatic setup procedure immediately. For the
accurate measurements, once you perform the next
operation, we recommend that you get out of the room
or move to the position that you do not interrupt the
accurate measurements (for example, along the wall
with no speakers installed nearby).
Notes
Optimizer microphone
Notes
✓
✓
✓
Equalizing
Level
Result
Retry
Exit
Detail
Setup
Measurement Over
Successfully