NOTE
• Adjust the frequency, and check that the impedance value is shown in the HOME screen.
However depending on the characteristics of the connected speaker, there might be cases in which
the impedance cannot be detected even if the frequency is changed. Also, if the frequency is
lowered too far, it might be heard as an audible sound; in this case, raise the frequency.
⑤
HIGH THRESH (HIGH THRESHOLD)
This specifies the upper limit of impedance that is considered normal.
⑥
LOW THRESH (LOW THRESHOLD)
This specifies the lower limit of impedance that is considered normal.
7.6. POWER SUPPLY
①
PwON DFLT (POWER ON DEFAULT)
When power is applied to the unit, this selects whether the unit starts up in standby mode (STANDBY) or in the
same state (POWER ON or STANDBY) as when the power was last disconnected (PREVIOUS).
②
PwON DELAY (POWER ON DELAY)
Specifies the time until the amp’s power supply starts when switching from STANDBY to POWER ON. In cases
such as when multiple amps start up simultaneously, you can set this to provide a time lag so that circuit
breakers are not tripped.
NOTE
• If the power is switched from the front panel, switching happens immediately, regardless of this
setting.
7. SETUP screen
PC412-D PC412-DI PC406-D PC406-DI Owner’s Manual |
39