Number
Alert
Message
Log
Message
SEVERITY
Content
Action
61
Dante Module
Failed
DANTE MODULE
FAILD
FAULT
The internal Dante
module is not
working correctly.
It might be that the
unit has
malfunctioned.
Contact your
Yamaha dealer.
62
Dante Module is in
Fail Safe Mode
DANTE FAIL SAFE
ERROR
The internal Dante
module is in Fail
Safe mode.
Because of a failed
update etc., the
Dante module’s
firmware was not
correctly written. In
Dante Firmware
Update Manager,
select Safe mode
and rewrite it.
63
Firmware Versions
Mismatch
-
ERROR
The version of this
unit’s firmware is
not compatible
with the version of
the Dante
firmware.
The updater
provided on the
website contains
the firmware for
this unit and the
Dante firmware as
a set. Update both.
64
Dante Is Not
Working By Giga
Bit
DANTE NOT
GIGABIT
ERROR
The network is not
connected at 1 GB.
In Daisy Chain
mode, this alert
also occurs when
connected to the
Control Port.
If this unit is
disconnected from
the network, alert
69 occurs, and this
alert is temporarily
cleared.
Use a 1GB network
switch.
65
Dante Is Working
At Secondary
WORK AT
SECONDARY
WARNING
In Redundant
mode, Dante audio
communication is
occurring on the
Secondary circuit.
If this unit is
disconnected from
the network, alert
69 occurs, and this
alert is temporarily
cleared.
Check whether the
primary circuit may
have
malfunctioned.
66
Error Occurred At
Secondary Port
ERROR AT
SECONDARY
WARNING
In Redundant
mode, the Dante
Primary circuit is
operating correctly,
but the Secondary
circuit is not
connected.
* Only if
connection had
once been
confirmed, and
then been
disconnected
If connection of
the Secondary
circuit is needed,
check whether it
may have
malfunctioned.
13. Reference
80
| PC412-D PC412-DI PC406-D PC406-DI Owner’s Manual