Number
Alert
Message
Log
Message
SEVERITY
Content
Action
67
Wrong Word Clock WRONG WORD
CLOCK
WARNING
A problem was
detected in the
word clock.
- In Dante
Controller,
correctly set the
word clock of the
entire system.
- Make sure that
the Fs (sampling
frequency) setting
is the same for the
devices whose
audio is patched.
68
Unit ID Mismatch
-
ERROR
The UNIT ID and
the Dante Device
Label do not
match.
Defeat restrictions
such as the Dante
Device Lock
function and the
Dante Domain
Manager function,
and then change
the UNIT ID.
69
Dante Port Is Not
Connected
DANTE PORT IS
NOT CONNECTED
WARNING
In Redundant
mode, the Dante
Primary circuit is
operating correctly,
but the Secondary
circuit is not
connected.
* This is displayed
only if connection
had once been
confirmed, and
then been
disconnected.
If this unit is
disconnected from
the network, alert
69 occurs, and this
alert is temporarily
cleared.
Make sure that the
Dante circuit is
correctly
connected.
• shows the channel name (1-4, A-D)
■
Sync Message
ID *
Message
Description
Possible Solution
-
NORMAL
Operating normally
-
-
NOT READY
The Dante module is being
prepared.
Wait until startup or synchronization is
completed. It may take up to 45 seconds
for this to be completed.
E01-03
WRONG WORD
CLOCK!
The word clock setting is
incorrect.
On the Dante Controller, set the clock
master and the sampling frequency
correctly.
E01-04
DANTE PORT DOES
NOT HAVE
CONNECTION!
The Dante network is not
connected.
Check whether an Ethernet cable might be
disconnected or broken.
E01-05
DANTE
CONNECTION
ERROR!
Other Dante devices cannot be
found because the Dante
network connections are
incorrect.
Check whether the Ethernet cable
connections are correct.
13. Reference
PC412-D PC412-DI PC406-D PC406-DI Owner’s Manual |
81