![Yamaha MY8-LAKE Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/yamaha/my8-lake/my8-lake_owners-manual_902756007.webp)
MY8-LAKE Owner’s Manual
7
Part Names and Functions
1
AES/EBU connector
This is a D-sub 25-pin connector that inputs and outputs eight digital audio signals in AES/
EBU format.
Supported sampling frequencies are 44.1, 48, 88.2, and 96 kHz.
2
NETWORK connector
This is a RJ-45 connector (100 Mbps) that connects to a PC (Lake Controller).
3
LED indicators
•
SELECT:
The white LED is lit (static) to confirm device selection from within the Lake
Controller software; it flashes when the Lake Controller is communicating with the device,
and is off when neither selection nor communication is occurring.
•
FAULT:
The red LED is either lit (static) or flashes to warn that a serious problem is
occurring. A fault can include an internal error, a slipping digital clock, module output
clipping, or a problem on the card interface.
For additional information about LED indications and their meaning, refer to the section
“Problems and Warnings” in the chapter “Appendix.”
•
STATUS:
The green LED flashes to indicate that the MY8-LAKE card is correctly booted
and operational; it is lit (static) when the digital input clock is locked.
1
2
3