TIP
Connect the positive lead (Red) to the positive (+) bat-
tery terminal first, then the negative lead (Black) to the
negative (–) battery terminal. Do not reverse these
positions.
WARNING
9
Be sure to insulate battery leads to prevent
arcing when the battery is not installed.
9
Disconnect the battery charging output lead.
Then insulate the connector by folding it back
on itself and carefully wrapping it with electri-
cal tape to prevent electrical contact with
ground (earth) or any other leads.
9
Remove the battery leads from the generator.
w
Connector
e
Battery lead
r
Electrical tape
5. Connect the negative lead (Black) to the negative
(–) battery terminal.
9
Screw
0
Negative lead (Black)
q
Negative battery terminal
1
Ground (Earth) Terminal
Make sure to ground (earth) the generator.
Check “SAFETY INFORMATION” (See page 4).