On starting the engine
Each indicator light flashes 5 times upon starting.
When starting the engine, make sure that each indica-
tor light flashes 5 times.
WARNING
9
If the indicator lights do not flash 5 times upon
starting, discontinue generator use immediate-
ly and consult a Yamaha dealer. The CO
SENSOR system may be malfunctioning.
9
If the CO SENSOR WARNING indicator light
(red) is flashing, immediately clear the area of
all people and animals while moving the gen-
erator to an open, outdoor area. Once the gen-
erator is relocated to a well-ventilated area, it
can be restarted after 5 minutes. Be sure to
point the exhaust away from people and build-
ings. Thoroughly ventilate the location where
the generator had stopped.
9
If the CO SENSOR system is malfunctioning, it
cannot warn you of potential high concentra-
tions of carbon monoxide. Move the generator
to a well-ventilated location and consult a
Yamaha dealer.
9
While the CO SENSOR is activated, the engine
cannot be restarted for approximately 5 min-
utes. Relocate the generator and address
symptoms of carbon monoxide poisoning
prior to restart the generator.
NOTICE
If you stop the engine in the following situations,
the CO SENSOR system may not be able to restart
the engine immediately. Wait approximately 15 sec-
onds before restarting the engine.
9
By the engine switch.
9
By the oil level warning device.
9
By running out of gasoline.
TIP
If the indicator lights come on or flash abnormally,
check “TROUBLESHOOTING” (See page 56).