For Service Engineer
Service Information
SI1604009E-002= S20, S10, M20, M10 and D10 installation procedures
31/34
When carrying in a machine
The cold machine carried inside the building
The condensation process
Indoor temperature:
20 deg C
Humidity: 60%
The temperature of the
machine is almost the
same as the outside air
temperature after being
exposed to the open air.
Outside air
temperature:
10 deg C
Indoor temperature: 20 deg C
Humidity: 60%
Temperature of the
machine: 10 deg C
Cold mounter 10deg C
?
Indoor temperature:
20 deg C
Humidity: 60%
The dew condensation occurs due to the air
whose temperature has dropped below 12 deg C.
The air is chilled by the cold surface of the machine.
The amount of saturated vapor of the chilled air
decreases.